Fountain units
20
Installation, operation and maintenance manual; Dancer jet
[en]
3
OPERATION AND MAINTENANCE
IMPORTANT: Protect the water outlet from the wind and do not operate the unit in strong wind.
If the unit is installed in an area frequently exposed to strong wind, it is possible that the wind
will displace the water outlet.
3.1
ON MODE AND GENERAL SETTINGS
-
The unit is switched on and controlled (movement, lighting, jet nozzle height) from the
fountain’s general control panel, which is not included with this unit (see chapter 2.2).
-
The shaft’s angle of movement can be restricted using the two stoppers on the guide bar
on the motor of the main shaft (
④
, Halospots only).
3.2
LIGHTING
The lighting does not form part of this unit. See the documentation of the lighting installed.
3.3
MAINTENANCE
For the maintenance of the components made of stainless steel, see the manual attached.
It is recommended that the unit be run in maintenance mode once a month to check that the
shaft is working properly.
Check the state of repair of the mechanical seal two years after installation. Once this time has
elapsed, complete this check every three months.
4
TECHNICAL SPECIFICATIONS
Input voltage
230 V AC
Jet nozzle diameter
16/20 mm
Power load (without lighting)
160 W
Water inlet connection
1-
½
” G
IP protection rating (IEC 60529)
IP68
5
FAQS
Question
Answer
Why isn’t the water coming out of the jet
nozzle properly? (speed, height)
Check the pump is working properly.
Check the inside of the nozzle. It should free
of all deposits and blockages.
Why isn’t the unit moving?
Check the control panel is properly
assembled.
Check that the unit has not been disabled by
a programmed timer.