Code 0000138008
rev. 1.0
3
•
It’s possible to enable(ON) or disable (OFF) the communication.
§
wdg config.
•
Adjust value with and
•
It’s possible to set as: Hardware Reset, Com. Reset, Stop Dosage and
WDG Alarm (default value).
§
rs485 watchdog
•
Adjust value with and
•
It’s possible to adjust the time in seconds. If it is set as OFF (default value)
the communication watchdog is disabled.
§
address
•
Adjust value with and
•
It’s possible to adjust the address of the device from 1 (default value) to 247
§
parity
•
Adjust value with and
•
The value of the parity bit, it’s possible to set as: Even (default value), Odd
or No.
§
baudrate
•
Adjust value with and
•
The value of the speed of the transmission, it’s possible to set as: 2400,
4800, 9600 (default value), 19200.
•
o
Setpoint 7.4ph
o
Adjust value with and
§
It’s possible to adjust from 0 to 14 pH value and 0 to 1000 mV for Redox
o
Setpoint Type Acid
§
Adjust value and
§
It’s possible to adjust Acid or Alkaline dosing and High or Low for Redox
o
OFA Time off
§
Adjust value and
§
It’s possible to adjust OFA time in minutes
Содержание CONTROL BASIC PLUS