S I G N A T U R E
0
The power supply was designed in accordance with the EN 61558 European Standard.
The electrolysis cell and the sensor holder were designed for use in pools with a maximum
temperature of 40ºC, with pH, hardness and alkalinity levels within the limits stated in the
corresponding regulations. Water should be maintained within the parameters shown below:
pH
7. – 7.6
Alkalinity
80 – 50 ppm
Isocyanuric
0 – 30 ppm
SENSOR HOLDER
The AstralPool Chlore Elite systems are supplied with a sensor holder that allows easy installation
of the control and safety elements included with the unit (pH/ORP sensors and external flow
detector), as well as other items such as an injection valve for pH control or an additional ground
connection. This sensor holder allows direct gluing to 63 mm PVC pipes.
EXTERNAL FLOW DETECTOR
The AstralPool Chlore Elite systems have a double flow detector that avoids the operation of the
system in the absence of a suitable water flow through the electrolysis cell, ensuring this way
its optimal operation at any moment.
INTEGRATED PH/ORP CONTROLLER
The AstralPool Chlore Elite systems include an integrated pH/ORP controller, adding to the
advantages of the salt electrolysis treatment of the swimming pool water, the self-control of the
recommended values of pH and ORP, and providing an integral and automatic treatment of your
swimming pool water.