Inst253 Astral Heat Pumps V07.13
11
OFF
F66 Period 3 end time
00
:
00—23
:
59
OFF
00
:
00
-
F69 Run Mode
0/1
0
-
0
:
Automatic
1
:
Economical
System
setting
F80 Password
OFF
0001 -- 9999
OFF
-
OFF means no password
0000 means clearing
password
F81 Temperature unit
C/F
C
-
C:
Centigrade
F: Fahrenheit
F85
Display accumulative
running time
-
-
hour
F86
Accumulative running
time reset
-
-
-
F87 Probation time
OFF
1 -- 9999
OFF
hour
The controller will stop if the
accumulative time is over
probation time, and show the
alarm code “A99”.
OFF means no probation
time
Testing
F98 Reserved
F99 Test self
This function can attract all relays in turn, and please don’t use it
when the controller is running!
End Exit
T
Basic Operating Principle
$
Temperature controlling
The controller has 3 temperature controlling mode: Refrigeration,Heat and auto(F29).Temperature
controlling point is controlled by “setting temperature (F11, or press the “set” key for some time to
set)” , “temperature difference(F12)”and “Auto mode temperature difference”.In refrigeration mode (4
way Valve is enable and follow compressor), the controller begins to refrigerate when the temperature
of the temperature sensor is over “setting temperature
+
temperature difference”, and it stops
refrigerating when the temperature is under “setting temperature
-
temperature difference”; In heat
mode (Valve is disable except when defrosting), the controller begins to heat when the temperature of
the temperature sensor is under “setting temperature
-
temperature difference”, and it stops heating
when the temperature is over “setting temperature
+
temperature difference”;In auto mode,the
controller begins to refrigerate when the temperature of the temperature sensor is over “setting
temperature
+
Auto mode temperature difference”, and it stops refrigerating when the temperature is
under “setting temperature”, the controller begins to heat when the temperature of the temperature
Содержание BPM400A
Страница 2: ...Inst253 Astral Heat Pumps V07 13 2 ...
Страница 22: ...Inst253 Astral Heat Pumps V07 13 22 WIRING DIAGRAMS BPM400 BPM600 ...
Страница 23: ...Inst253 Astral Heat Pumps V07 13 23 WIRING DIAGRAMS BPM700 BPM800 ...
Страница 24: ...Inst253 Astral Heat Pumps V07 13 24 WIRING DIAGRAMS BPT900 ...
Страница 27: ...Inst253 Astral Heat Pumps V07 13 27 ...