background image

Astor-Bannerman (Medical) Ltd.

Unit 11F Coln Park Industrial Estate

 

Andoversford, Cheltenham

 

Gloucestershire

GL54 4HJ

Tel: 01242 820820

E-

mail: [email protected]

W

eb

: www.astorbannerman.co.uk

Directors: Dr. K D Kwok

 

MBBS MRCP  

  

J Stuart-Smith

 

MBA BSc

 

   

P G Deverson

 

MIOM

 

Company registered in England No. 2849299    VAT No. 630 6090 68

Manufacturers Name:

Manufacturers Address:

Equipment Type:

 

ABW-CP Height adjustable basin

I hereby declare that the above product conforms to the following specification:

%%#

 

-EDICAL

 

$IRECTIVE

%.

 

%LECTRICAL

 

3AFETY

%.

1

 

%-#

 

%.

 

!SSISTIVE

 

PRODUCTS

 

FOR

 

PERSONS

 

WITH

 

DISABILITY

Signed: 

Technical Director

Astor-Bannerman (Medical) Ltd

Unit 11F Coln Park
Andoversford
Cheltenham
Gloucestershire
GL54 4HJ

For and on behalf of Astor-Banne

r

man (Medical) Ltd

 

Date:

 

 

09/

9

CERTIFICATE OF CONFORMITY

Page: 

1

1

 Version 

4

 : 

2

5

-0

9

-01

9

Содержание ABW-CP

Страница 1: ...Warranty No Version 4 25 09 019 ABW CP Height Adjustable Basin INSTALLATION and USER GUIDE ...

Страница 2: ...ver further clockwise will make the water hotter then rotating the lever anti clockwise will make the water colder To turn the water off rotate the lever anticlockwise as far as it will go Our policy is one of continuous improvement and we therefore reserve the right to make technical alterations without notice The content of this publication may not be copied either whole or in part without the c...

Страница 3: ...ng In the unlikely event that problems occur with the unit carry out the following easy checks to determine whether or not an engineer is required Fault The rise and fall unit does not travel up or down Cause The mains power supply may have been disconnected Remedy Examine the mains fuses circuit breakers and reset as necessary and ensure that mains voltage is fully reconnected If the unit still f...

Страница 4: ...eight 50Kg A weighted sound emission 70dB A Our policy is one of continuous improvement and we therefore reserve the right to make technical alterations without notice The content of this publication may not be copied either whole or in part without the consent of Astor Bannerman All dimensions in mm Fig 3 Version 4 25 09 019 ...

Страница 5: ... 30v and transformed to 4v within the unit A 30mA RCD protected fused spur is required with a flush mounted flex outlet cover on the wall behind the unit at a height of 1100mm from the floor on the centreline of the unit Fixing The basin assembly should be fixed to a load bearing wall i e strong enough to carry a 100kg load on wall fixing which is flat and free from obstruction from 200mm 2200mm above ...

Страница 6: ... drill two full depth pilot holes at the marked positions and then open up in order to accept the appropriate fixings Fix the attachment rail onto the wall with the open lip uppermost using two suitable fixings Ensure that the rail is horizontal using a level adjust to suit and check that it is secure Installation Please Note Due to the complexity of different building methods Astor Bannerman do n...

Страница 7: ...en mark the wall through the three attachment points one on the upper and two on the lower horizontal beams see Fig 8 below Remove the unit from the wall and at each of the three marked positions drill a 6mm full depth pilot hole Open these three holes to accept appropriate fixings Fit the fixings into the wall With assistance place the rise and fall unit back onto the wall mounted rail ensuring i...

Страница 8: ...Fig 9 above and page 10 of tap manufacturer s instructions steps 1 3 but DO NOT CONNECT THE HOSES YET Fit the basin assembly to the high low frame Remove the protective film from double sided sticky tape fitted to the pivoting arms and place the basin onto the support arms as far back as possible ensuring the basin is under the white plastic upper cover Plumb in the tap Fit the plumbing to the tap...

Страница 9: ...tap connector already fitted Fit the tap body to the base see page 10 of tap manufacturer s instructions step 4 only DO NOT TURN ON THE WATER SUPPLIES YET Fit the mains water supply Fit the white plastic lower and upper covers and waste assembly Remove retain the mushroom heads from the four plastic rivets found in the packing kit Fit the lower cover and align the holes in the cover with the holes...

Страница 10: ...cument to the client Test and set the tap Turn on both water supplies and move the tap handle to both cold and hot positions letting the water flow for a few minutes to finish flushing through the system With the handle in the hottest position check the temperature of the water is 41ºC and correct if necessary see page 19 of tap manufacturer s instructions Fit the cap back onto the trunking Test t...

Страница 11: ...299 VAT No 630 6090 68 Manufacturers Name Manufacturers Address Equipment Type ABW CP Height adjustable basin I hereby declare that the above product conforms to the following specification EDICAL IRECTIVE LECTRICAL 3AFETY 1 SSISTIVE PRODUCTS FOR PERSONS WITH DISABILITY Signed Technical Director Astor Bannerman Medical Ltd Unit 11F Coln Park Andoversford Cheltenham Gloucestershire GL54 4HJ For and...

Страница 12: ...hout notice The content of this publication may not be copied either whole or in part without the consent of Astor Bannerman Medical Limited Original Document Page 12 Astor Bannerman Ltd Unit 11f Coln Park Industrial Estate Andoversford Cheltenham GL54 4HJ Email sales astorbannerman co uk Tel 44 0 1242 820820 Fax 44 0 1242 821110 Version 4 25 09 019 ...

Отзывы: