Speed mode 

Defines the ASTEL protocol communication baud rate. 
 

Value

 

FUNCTION

 

LOW speed – 1200 bps 

MID speed – 2400 bps 

HIGH speed – 4800 bps 

 
 
Number of addressable lights 

This defines how the OUT is acting. There are two basic modes: 
 

-non addressable – all the lights on the control OUT light in the same way 

 

-addressable – there can be up to 15 address and each light connected to the OUT can have 

the address from 1 to 15 – each light with different address can light different. There can be more 
than one light with the same address – the number of the lights with the same address is not limited! 
 
To set-up non addressable mode set the switches 1 - 4 to OFF. 
To set-up addressable mode set the switches 1 - 4 to the number of the lights with different 
addresses on the control OUT. 
Please pay attention the higher number results in lower refresh rate! 
 
 

Data type 

This defines the number of data bytes used for light / the number of DMX channels for each light on 
the control OUT. 
 

Value

 

FUNCTION

 

1 byte - not used 

2 bytes - not used 

3 bytes - RGB lights 

4 bytes - not used 

 
Non addressable mode: 
The number of used DMX channels is same as the defined. 
 
Addressable mode: 
The number of used DMX channels used for control OUT is as follows: 
 
DATA TYPE number x number of ADDRESSABLE LIGHTS 
 
Example: 
DATA TYPE = 2 – 3 bytes 
Number of ADDRESSABLE LIGHTS = 5 
DMX channels used = 3 x 5 = 15 
 
 

Set default 

Sets the parameters to their default values: 
 

Parameter Value 
Speed mode 

Number 0 
Data type 

Содержание MXU01

Страница 1: ...MXU01 DMX512 INTERFACE Operating Instructions ...

Страница 2: ...ons 3 Controls and Connectors 4 DMX512 Interface MXU01 4 Installation 5 Set up 6 Appearance 8 Technical Specifications 8 Warranty 9 Declaration of Conformity 10 ________________________________________________________________________________ ...

Страница 3: ...ower Consumption Polarity Protection Transient Protection Short Circuit Output Protection Simple Installation PRECAUTIONS The DMX512 Interface MXU01 has to be installed and used in accordance with the instructions of this manual only The power supply has to be disconnected before installation Avoid installing the DMX512 Interface MXU01 in extremely hot places and near appliances generating strong ...

Страница 4: ...minal block connector to connect 12 24Vdc power supply 2 OUT Control output to connect the Control P and GND Control wires of multi color RGB lights EQUATOR series or PWM dimmer MDU13 3 CONTROL The 3 pole terminal block connector to connect DMX512 line 4 DMX SETTINGS DIP switch to set the DMX512 and ASTEL protocol commmunication parameters ...

Страница 5: ...tallation F2A ASTEL PROTOCOL OUTPUT CONTROL GND F2A DMX SETTINGS DMX IN C DC IN D D 1 2 3 4 5 6 7 8 9 10 11 12 ON DMX512 LINE D D GND OUT MXU01 Power supply connection The power supply has to be connected through the switch not included and protected by a fuse not included to the DC IN terminal block connector with correct polarity The power supply voltage has to be from 10 30Vdc ASTEL protocol ou...

Страница 6: ...ation The DIP switch is used to set up the mode of operation and programming DIP switch switches FUNCTION 1 4 Parameter 5 8 Mode of operation 9 10 Not used 11 Programming trigger 12 Programming mode The set up procedure 1 Set the switch 12 to ON position 2 Set the programming mode with the switches 5 8 as described below 3 Set the parameter value as described below 4 Set the switch 11 to ON positi...

Страница 7: ...e switches 1 4 to OFF To set up addressable mode set the switches 1 4 to the number of the lights with different addresses on the control OUT Please pay attention the higher number results in lower refresh rate Data type This defines the number of data bytes used for light the number of DMX channels for each light on the control OUT Value FUNCTION 0 1 byte not used 1 2 bytes not used 2 3 bytes RGB...

Страница 8: ...witches 5 8 to ON position 9 Set the light new address to 1 15 with the switches 1 4 10 Connect the light to the power supply and IMMEDIATELY continue with step 11 11 Set the switch 11 to ON position 12 Wait for 5 seconds 13 Set the switch 11 to OFF position 14 Set the switch 12 to OFF position APPEARANCE 21 DMX SETTINGS DMX IN OUT C DC IN D D 1 2 3 4 5 6 7 8 9 10 11 12 ON MXU01 67 80 TECHNICAL SP...

Страница 9: ...the Purchaser at the Warrantor s expense d no refund of the purchase price will be granted to the Purchaser unless the Warrantor is unable to remedy the defect after having a reasonable number of opportunities to do so Prior to refund of the purchase price Purchaser must submit a statement in writing from a professional boating equipment supplier that the installation instructions of the Operating...

Страница 10: ... and Model Number 1 DMX512 Interface MXU01 conform to the following Product Specifications EMC EN 55103 1 2009 A1 2012 Safety EN 62368 1 2014 Supplementary Information The products herewith comply with the requirements of the following Directives and carry the CE marking accordingly the Low Voltage Directive 2014 35 EU the EMC Directive 2014 30 EU the RoHS Directive EU 2015 863 ASTEL d o o Dutovlj...

Страница 11: ...11 ...

Страница 12: ...12 ASTEL d o o Dutovlje 138 6221 Dutovlje Slovenia Tel 386 5 7310771 386 5 7310772 Fax 386 5 7310789 E mail info astel marine com Web www astel marine com ...

Отзывы: