background image

 

Power Supply Unit MPS021000 / MPS021500 

 

 

 

 

 

(1)  LIGHT 

Terminal-block connector to connect the LED underwater light using 4-pole multi-core cable. 

 

(2)  CONTROL 

Terminal-block connector to connect optional remote control unit or switch. 

 

(3)  DC IN 

Terminal-block connector to connect 24Vdc power supply. 

 

(4)  DC OUT 

Terminal-block connector to connect to the DC IN connector of another power supply unit. 

 

 

 

Содержание MPS021000

Страница 1: ...PLAQUE MFM0680 UNDERWATER LIGHT Operating Instructions ...

Страница 2: ...M0680 4 Power Supply Unit MPS021000 MPS021500 5 Installation 6 Underwater Light PLAQUE MFM0680 6 Power Supply Unit MPS021000 MPS021500 7 Appearance 9 Technical Specifications 9 Warranty 10 Declaration of Conformity 11 _________________________________________________________________________________ ...

Страница 3: ...on Simple Installation Remote Control optional PRECAUTIONS The underwater light has to be installed and used in accordance with the instructions of this manual only The power supply has to be disconnected before installation The underwater light is recomended to be installed around 0 2 m below the waterline for the best illumination and to avoid over heating Do not try to install or remove the und...

Страница 4: ...r light casing Aluminium bronze casing with fixing holes and cable gland 3 Fixing assembly The fixing nut washer and screws to fix the underwater light on the hull 4 Cable The 4 pole multi core cable to connect the power supply unit 5 Heat sink The aluminium heat sink to enable properly temperature stability of the underwater light ...

Страница 5: ... underwater light using 4 pole multi core cable 2 CONTROL Terminal block connector to connect optional remote control unit or switch 3 DC IN Terminal block connector to connect 24Vdc power supply 4 DC OUT Terminal block connector to connect to the DC IN connector of another power supply unit ...

Страница 6: ...mperature sensor against over heating When the temperature of the underwater light exceeds 60 C the power supply unit starts to reduce the current of the LEDs If the temperature of the underwater light exceeds 90 C the underwater light is automatically switched off Hull preparation The underwater light is recomended to be installed around 0 2 m below the waterline for the best illumination and to ...

Страница 7: ... paint the entire underwater casing exposed to the water with anti foul paint Power Supply Unit MPS021000 MPS021500 The MPS021000 MPS021500 has to be installed near the underwater light inside of the vessel Avoid the installation in extremely hot places and near appliances generating strong magnetic fields An extension cable can be used in case of longer distance between the underwater light and t...

Страница 8: ...LIGHT PLAQUE MFM0680 wire colour FUNCTION 1 Brown LED1 2 Orange LED1 3 Red Temperature sensor 4 Black Temperature sensor Remote control connection Remote control optional can be connected to the CONTROL terminal block connector to turn on and turn off and to control the luminosity of the underwater light To remotely turn on and turn off the underwater light the simple switch not included can be us...

Страница 9: ...te color temperature 6 000 10 000 K Operating temperature 10 C 50 C Casing Aluminium bronze AB2 Protection IP 68 Dimensions Ø110x135mm Weight 2 3 kg Power Supply Unit MPS021000 MPS021500 Input voltage 24 Vdc Consumption max 1 7 Adc Operating temperature 10 C 50 C Casing ABS Protection IP 65 Dimensions 127x111x55 5mm Weight 0 3 kg Design and specifications subject to change without notice ...

Страница 10: ... the Purchaser at the Warrantor s expense d no refund of the purchase price will be granted to the Purchaser unless the Warrantor is unable to remedy the defect after having a reasonable number of opportunities to do so Prior to refund of the purchase price Purchaser must submit a statement in writing from a professional boating equipment supplier that the installation instructions of the Operatin...

Страница 11: ...t MPS021000 MPS021500 conform to the following Product Specifications EMC EN 55015 2006 A1 2007 A2 2009 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 EN 61547 2009 Safety EN 61347 1 2008 A1 EN 61347 2 13 2006 Supplementary Information The products herewith comply with the requirements of the following Directives and carry the CE marking accordingly the Low Voltage Directive 2014 35 EU the EM...

Страница 12: ...12 ASTEL d o o Dutovlje 138 6221 Dutovlje Slovenia Tel 386 5 7310771 386 5 7310772 Fax 386 5 7310789 E mail info astel marine com Web www astel marine com ...

Отзывы: