![ASTEL LIGHTING METEOR LSR0640EQ Series Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/astel-lighting/meteor-lsr0640eq-series/meteor-lsr0640eq-series_operating-instructions-manual_2989732006.webp)
6
Connection
The power supply has to be connected through the main switch (not included) with correct polarity
and protected by a fuse (not included). The power supply voltage has to be from 10 - 30Vdc.
Note:
•
The power supply has to be switched off before installation.
The underwater light has to be connected as described in the table below:
METEOR LSR0640EQ
wire color
FUNCTION
Red
+ DC Power Supply
Black
GND Power Supply
Orange
+ Control
Brown
GND Control
Remote control and network connection
Single-color cool white (W), warm white (WW), blue (B) or green (G) models
To remotely turn-on and turn-off the underwater pool light the simple switch (not included) can be
used and connected to the CONTROL wires by a 2-pole signal cable (not included).
Note:
•
If the remote control is not used at single-color models for normal operation the both
CONTROL wires have to be bridged and insulated or connected to the GND.
Multi-color RGB (M), WGB (WM), RGBW (MW) models
To control the mode of lighting the simple momentary-switch (not included) has to be used and
connected to the CONTROL wires by the 2-pole signal cable (not included).
Optional LXU01 interface can be connected to the CONTROL wires by using a 2-pole signal cable
(not included).
Содержание METEOR LSR0640EQ Series
Страница 1: ...METEOR LSR0640EQ UNDERWATER POOL LIGHT Operating Instructions...
Страница 11: ...11...