SCSI Enclosure Services (SES)
Ver. B
Copyright © 2010 by Astek Corporation. All rights reserved
23
Voltage
Low Critical
Low Warning
High Warning
High Critical
12V
10.8V (-10%)
11.4V (-5%)
12.6V (+5%)
13.2V (+10%)
3.3V
2.97V (-10%)
3.14V (-5%)
3.47V (+5%)
3.63V (+10%)
1.8V
1.62V (-10%)
1.71V (-5%)
1.89V (+5%)
1.98V (+10%)
1.0V
0.9V (-10%)
0.95V (-5%)
1.05V (+5%)
1.1V (+10%)
Cooling Elements
SES will monitor fan speed on one connector and will monitor and control fan speed on three connectors.
There is a fan on the heatsink that cools the expander. The fan speed is monitored and reported through
SES. If the fan stops, the expander will report a failure through SES and illuminate the ERROR LED on
the front panel.
There are three fans that can be monitored and controlled through SES. The intent is for these three
connectors to be used for external fan control/monitoring. If one of these fans stops running, the
expander will NOT report a failure NOR illuminate the ERROR LED on the front panel.
Power Supply Element
The expander will monitor the status of the Power Supply connected to pin 8 of the Enclosure Services
Header. When/if this pin is driven low, the expander will report a failure through SES and illuminate the
ERROR LED on the front panel.
SAS Expander Element
The expander element contains information about the A33606-PCI-01 product such as product name,
revision, firmware version, etc.
Customization
Many of the SES settings and data can be customized to the application needs. Contact Astek to obtain a
customized expander configuration to make your product stand out from the crowd.