PHOENIX Talon - Operation and Service Manual
7
Receiving and Inspection
Upon receipt of the Burner:
1. Check each item on the bill of lading and/or invoice to determine that all the equipment that was
shipped has been received.
2. Carefully examine all of the equipment, assemblies and subassemblies to check if there has been
any damage in shipment.
3. If there are any damaged or missing parts, contact ASTEC Burner Systems Group for assistance.
(423-867-4210, or FAX 423-827-1560)
NOTE:
If the installation is delayed and the equipment is to be stored outside:
1. Provide adequate protection, as dictated by your climate and the period of exposure.
2. Special care should be given to all; motors, hydraulics, electrical parts, and bearings, to protect them
from rain, snow, or excessive moisture.
Burner Capacity
Table - 1 Burner Capacities
Notes: For Table-1
1. The maximum BTU/hour rating is based on 20% excess air.
2. The figures used in Table
– 1 are based on: 60Hz AC, and Standard Cubic Feet per Hour (SCFH), at
70F air temperature, at sea level.
3. Correction factors must be applied for altitude or temperature variations. (See Altitude Correction
Chart.)
4. Viscosity of the oil delivered to the burner at 220
o
F must be 80 SSU (maximum) or lower.
5.
The system exhaust fan must have enough capacity to provide a slight negative pressure (0.20” to
0.30" water column) at the burner breech plate. (This will exhaust the products of combustion, and
prevent “puffing” at the breeching plate.)
6. The air flow in the PHOENIX Talon can be monitored using the pressure tap on the side of the burner
blower housing. (The air pressure for a given flow is in the individual burner capacity tables.)
7. The values of differential pressure versus flow is listed in the individual burner capacity sheets.
8. The air required to atomize the fuel is provided by compressed air during oil firing. (See note-4)
9. The gas flow in the PHOENIX Talon can be measured using the orifice plate provided in the gas line.
BURNER
MODEL
AIR
FLOW
SCFH
AIR
FLOW
SCFM
BURNER
BLOWER
HP
NATURAL
GAS
SCFH
OIL
FLOW
GPM
MAXIMUM
CAPACITY
BTU/HOUR
PT-50
660,000
11,000
40
55,000
6.5
55,000,000
PT-75
1,000,000
16,667
60
83,000
10
83,000,000
PT-100
1,284,000
21,400
75
110,000
13
110,000,000
PT-125
1,600,000
26,667
100
137,000
16
138,000,000
PT-150
2,000,000
33,333
125
165,000
20
165,000,000
Содержание PHOENIX Talon
Страница 1: ...Version 3 8 8 2011 OPERATION AND SERVICE MANUAL ASTEC Burner Group ...
Страница 2: ...PHOENIX Talon Operation and Service Manual 2 ...
Страница 9: ...PHOENIX Talon Operation and Service Manual 9 Illustration 1 Illustration 2 ...
Страница 10: ...PHOENIX Talon Operation and Service Manual 10 Illustration 3 ...
Страница 18: ...PHOENIX Talon Operation and Service Manual 18 Oil Fuel Piping System Illustration 8 Oil Train Heavy Oil Shown ...