Manual switching amplifier BS 805 

Page 6 of 12 

Subject to technical change 10/2017 

A.S.T. Angewandte SYSTEM-TECHNIK GmbH Dresden 

5.2.  Example 

 

 
 

6.  Information on Performance-Level PLc in accordance with DIN EN 13849-1 

6.1.  Classification of Type Series “Switching Amplifier BS 805” 

 
The  Switching  Amplifier  BS805  can  be  classified  in  the  Performance-Level  PLc  in  accordance  with  the  set  of 
standards governing Safety Relevant Control Systems DIN EN 13849-1. 
This then covers hazards as shown in the hazard graphs below recommended for safety-relevant control systems in 
conjunction with the Performance-Level PLc and SK1 Category. 
 

 

 

 
 
 
 
 Severity of injury 

(S)

 

 S1 Slight injury (usually temporary) 
S2 Severe injury (usually irreversible), 
including death 
 
Frequency and/or duration of exposure to 
hazard 

(F)

 

F1 ... Seldom to quite often and/or short  
         duration of exposure 
F2 ... Frequent to permanent and/or short  
         duration of exposure 
 
Possibility of preventing the hazard (

P) 

 

P1 ... Possible under certain conditions 
P2 ... Hardly possible 
 
 
 

6.2.  Error detection in operation with a connected sensor 

 
The Switching Amplifier BS805 identifies the following errors: 
Sensor monitoring 

Wire breakage, also on single core of sensor cable. 

Short circuit on any number of cores of sensor cable. 

“Unsafe” connection of individual cores. 

 
Internal monitoring 

Failure of operating voltage 

Failure of sensor power supply 

 
The BS 805 is responding to an error with: 

Relay SP1 and SP2 fall (to drop out) 

LED U78 blinking 

Output signal is 2mA 

 

sequence 

Operation for Code 341 

LED-display 

1. 

3-times

 press >T1< 

>U2-U4-U8< 

 

light 

2. 

Wait approx. 2 sec 

Light off 

3. 

4-times

 press >T1< 

>U2-U4-U8-U16< light 

4. 

Wait approx. 2 sec 

Light off 

5. 

1-times

  press>T1< 

>U2< light 

6. 

end 

LED >U16< flashing approx. 2 sec 

S

1

Starting

 point for

assessing

 risk

reduction

Low

risk

Required

performance

level PL

High

risk

a

b

c

d

e

F

1

P

1

P

1

P

1

P

1

F

1

S

2

F

2

P

2

P

2

P

2

P

2

F

2

Содержание BS 805.01

Страница 1: ...5 Original Manual Strain gauge switching amplifier BS 805 01 BS 805 11 BS 805 21 A S T Angewandte SYSTEM TECHNIK GmbH Dresden Marschnerstraße 26 01307 Dresden phone 03 51 44 55 30 fax 03 51 44 55 555 www ast de vertrieb dd ast de ...

Страница 2: ......

Страница 3: ...ED display 4 5 Function of key T1 5 5 1 Code table 5 5 2 Example 6 6 Information on Performance Level PLc in accordance with DIN EN 13849 1 6 6 1 Classification of Type Series Switching Amplifier BS 805 6 6 2 Error detection in operation with a connected sensor 6 6 3 Other functions 7 7 Commissioning 7 7 1 Mounting 7 7 2 Connection 7 7 3 Signal settings 8 7 4 Control of settings 9 8 Specification ...

Страница 4: ......

Страница 5: ...t must be installed and attached under adherence to of the current DIN and VDE standards ATTENTION The type BS 805 01 Strain Gauge amplifier has been designed to the purpose of amplifying the output signals of sensors with metal foil strain gauges preferably force transducers The type BS 805 02 has been designed to the purpose of amplifying the output signals of sensors with standard signal 4 20mA...

Страница 6: ...µC T1 SP2 1 T1 t Force transducer Power supply A Standard signal output 5 4 20mA BS 805 11 Force transducer Standard signal output Power supply 230VAC 0 V SI EX SI EX 1 X1 EX 2 EX 3 SI 4 SI 5 4 20mA 6 0mA SP1 1 X10 1 NC1 2 COM1 3 NO1 X11 1 NC2 2 COM2 3 NO2 X5 1 L 2 N µC T1 SP2 1 T1 t 3 PE 7 8 A X12 1 PE1 2 PE2 3 Operating elements BS 805 01 Strain gauge switching amplifier Supply voltage 10 30VDC ...

Страница 7: ...ifier Supply voltage 230VAC case IP65 die cast Setup V T1 LED i O U78 LED SP1 SP1 Cable gland M20 D 6 12mm Cable gland M16 D 5 10mm BS 805 21 Strain gauge switching amplifier Supply voltage 10 30VDC case IP40 DIN rail V T1 LED i O U78 LED SP1 SP1 SH SH PE PE EX EX NC1 NC2 COM1 COM2 NO1 NO2 SI SI 4 20 mA 0mA 24V Schaltverstärker BS 805 SP1 V 20 Power T1 mA 0 4 SP2 D ...

Страница 8: ...l operations Error flashing display U1 4mA incorrect code enter U2 4mA I 8mA U4 8mA I 12mA U8 12mA I 16mA U16 16mA I 20mA U32 20mA I U78 Ready for operation break or short in sensor wire blinks once Current level exceeded through EX for BS805 y1 bridge resistance 300 for BS805 y1 sensor current 40mA blinks twice Current level not attained through EX Only for BS805 y1 bridge resistance 1000 blinks ...

Страница 9: ...2mA 251 Relay 1 and Relay 2 Reset at normal 255 Constant current 4 0 311 mA 12 0 312 20 0 313 0 2 344 0 5 343 1 0 331 2 0 332 3 0 333 4 0 334 5 0 335 0 2 341 0 5 342 1 0 321 2 0 322 3 0 323 4 0 324 5 0 325 Example 16 8 12 0 5 0 0 2 312 335 341 Current to reset Back to measuring mode 355 or voltage supply 10 30VDC to break Element Function Code Basic setting only BS 805 01 SP1 normal without hyster...

Страница 10: ...on of exposure F2 Frequent to permanent and or short duration of exposure Possibility of preventing the hazard P P1 Possible under certain conditions P2 Hardly possible 6 2 Error detection in operation with a connected sensor The Switching Amplifier BS805 identifies the following errors Sensor monitoring Wire breakage also on single core of sensor cable Short circuit on any number of cores of sens...

Страница 11: ... designed for mounting on a standard rail 7 2 Connection The cables for the sensor the supply voltage and the signal output are to the strip_X1 to attach Protective conductors of the discharges for the switching signals are to be attached absolutely to the strip_X12 PE Standard contacting of cable shield to contact clip cable jacket and shield dismantle cut around the cable jacket 15mm behind the ...

Страница 12: ...ockwise Red LED remains on Extend zeroing range with functions 43x Whenever the appliance detects an error refer to point 4 LED display LED U78 an output current of 2mA is always generated and the red LED U1 lights up A note can be made of the test signal Code No Switch on 422 Switch off 423 for documentation purposes later on For this purpose de charge the sensor measure the output signal and con...

Страница 13: ...14mA 4mA 18mA Turn SP2 adjuster clockwise up to the very point where relay 2 just about switches over Switch to measuring mode applying function 355 When geared to the standard setting the relay de energises as soon as the switching point is attained The function 2x2 reverses the switching action and allows the relay to energise when the switching point is attained 7 4 Control of settings The sign...

Страница 14: ...pping Switching voltage switching current Normal Invers with T1 mA mA Sec LED display for Switching status 4 22 0 05 0 1 0 5 1 2 0 5 250V 6A adjustable Accuracy Reproducibility the settings Linear error plus hysteresis Temperature effect full load 20mA Temperature effect zero 4mA v E v E v E 10K v E 10K 0 5 0 2 0 2 0 2 Power supply Nominal voltage Current consumption A LED display for stand by 10 ...

Страница 15: ...Manual switching amplifier BS 805 Subject to technical change 10 2017 Page 11 of 12 A S T Angewandte SYSTEM TECHNIK GmbH Dresden 9 EC Declaration of Conformity ...

Страница 16: ...Manual switching amplifier BS 805 Page 12 of 12 Subject to technical change 10 2017 A S T Angewandte SYSTEM TECHNIK GmbH Dresden ...

Отзывы: