46 -
Model 12-1015 Users’ Manual Version 13.08
Associated Equipment Corp.
5043 Farlin Ave.
800-949-1472(US)
St. Louis, MO 63115
314-385-5178 (Outside US)
After that press key again and the results will be shown as below (Fig 66.)
10. If either minimum or maximum charging volts are not within the voltage
range limits then it will display one of the screen as below (Figures 66 &
67) and it will prompt you to check the alternator system for the fault.
11. To exit the program, pressing the key at any moment will exit and
return back to the main menu screen (Fig.57).
Figure 66
Figure 67
Figure 68
Results: Good
At 2,000 rpm,
Loading Test:
Average Charging
Volts: 13.3V
Results: Low charge
At 2,000 rpm,
Loading Test:
>13.5V: Max. 13.3V
Check for loose belt
and the alternator.
Results: Low charge
At 2,000 rpm,
Loading Test:
>12.5V: Min. 12.4V
Check for loose belt
and the alternator.