11. Press
key and the display will show: (Fig.28) below:
12. Referring to the Table list (Fig.27) basing on 80D26L, check the battery
type: WET, MF, Sealed MF or Closed MF (CMF) as each category has
different CCA ratings. For instance, if the battery is a Sealed MF (CMF)
then it is rated at 630 CCA.
Note: WET
- Wet
Cell
Type
MF
- Maintenance
Free
Type
SMF - Closed
or
Sealed
Maintenance
Free
13. To enter the value 630, press key will increase the original value of 100
(Fig.29) by step of 100 units to 600. Likewise use key to increase the
last two digits (00) to 30 by step of 5 units for each pressing. (See Fig. 29)
Once the CCA rating of the battery is confirmed, press
key will start
the testing process. Refer to the display below (Fig. 30).
Figure 28
Fig. 29
Input Battery Rating
Increase/decrease:
Single digit
By hundredth
500
CCA
[Enter] to proceed.
Input Battery Rating
Increase/decrease:
Single digit
By hundredths
630
CCA
[Enter] to proceed.