4
Association Table
Group ID
Maximum Nodes
Description
Commands
1
5
Lifeline
Command_Class_Battery, Battery_Report ;
Command_Class_Notification, Notification_Report;
Command_Class_Configuration, Configuration_Report;
Command_Class_Device_reset_locally,
Device_Reset_locally_notification
Notifications Table:
Alarm Reports
Alarm
type
Alarm Level
Description
Notification
Type
Event
Master Code
changed.
0x70
0x00
Master code was
changed at keypad
0x06
0x12
0xFB
Master code was
changed over RF
0x06
0x0E
User added
0x(01-max
users)
User added. Alarm
level = user slot
number
0x06
0X0E
User deleted
0x21
0x(01-max
users)
User was deleted.
Alarm level = user slot
number
0x06
0X0D(0X0C)
Tamper Alarm
0xA1
0x01
keypad attempts
exceed code entry
limit
0x06
0X10
0x02
front escutcheon
removed from main
0x06
0xFE
RF Operate Unlock
0x19
0x01
by RF module
0x06
0X04
Keypad Unlock
0x13
0x(01-max
users)
Where Alarm level
represents user slot
number (0xFB =
Master Code)
0x06
0X06
Manual Lock
0x15
0x01
by key cylinder or
inside thumb-turn
0x06
0x01
0x02
by touch function
(lock and leave)
0x06
0x01
0x03
By inside button
0x06
0x01