background image

 

500-23700 
Revision B 

6. 

Before handling any board, ENSURE dissipation of any bodily charge.

 

7. 

CHECK placement of all wiring before powering to ensure that moving door parts do 
not catch wires and cause damage to equipment.

 

8. 

ENSURE compliance with all applicable safety standards (i.e., ANSI A156.10/A156.19) 
upon completion of installation.

 

9. 

DO NOT ATTEMPT any repair of the sensor. 

10.  AVOID the following concerning unauthorized disassembly or repair: 

 

It may jeopardize personal safety and may cause exposure to the risk of 
electrical shock. 

 

It will void the product warranty. 

Installation / Wiring / Setup 

Installation 

1. 

MOUNT the WSS using the included mounting ring or in a standard plastic or 
metal electrical gang box, as applicable, and depending on the type of door 
installation. 

NOTE 1:

 

The weather resistant foam is used as a protective barrier against 
the elements.

 

NOTE 2: 

The plastic adapter ring enables the double gang face plate to 
attach to various plastic and metal gang boxes.

 

 

 

2. 

DO NOT ALLOW contact between the sensor and a metal gang box to prevent 
shorting the devices. 

3. 

ENSURE placement of the device so that motion from the door or other types of 
movement do not interfere with the detection zone. 

Содержание Securitron WSS Wave Sense

Страница 1: ...d mode OPERATING TEMPERATURE 4 F to 131 F 20 C to 55 C IMMUNITY Immune to electrical and radio frequency interference WEIGHT 0 34 lbs 0 15 kg REGULATORY Electromagnetic compatibility EMC according to 2004 108 EC FCC G9B MS08 IC 4680A MS08 Precautions 1 SHUT OFF power to power source before attempting any wiring procedures 2 MAINTAIN a clean and safe environment when working in public areas 3 Const...

Страница 2: ...ure to the risk of electrical shock It will void the product warranty Installation Wiring Setup Installation 1 MOUNT the WSS using the included mounting ring or in a standard plastic or metal electrical gang box as applicable and depending on the type of door installation NOTE 1 The weather resistant foam is used as a protective barrier against the elements NOTE 2 The plastic adapter ring enables ...

Страница 3: ... NOTE Sensing field may be adjusted from 4 to 24 a ROTATE the potentiometer to increase the sensing field NOTE 1 Toggle Mode is recommended for switch applications In Toggle Mode a detection activates the relay and a second detection deactivates the relay NOTE 2 Pulse Mode is recommended for automatic door applications In Pulse Mode a detection activates the relay for a short period of time depend...

Страница 4: ...ng output mode SWITCH the output mode to Pulse Mode 2 Wrong connection CHECK wiring and relay connection FCC Approval This device complies with Part 15 of the FCC Rules and with RSS 210 of Industry Canada Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause...

Отзывы: