APPENDIX A:  TROUBLESHOOTING 
PROBLEM-- Unit will not operate when trigger wire is connected to +V. 
On a new installation, make sure that DC power (12 or 24 volts depending on the model) is 

connected to the red and black wires with correct polarity.  When this is confirmed note that the 
UnLatch will never operate unless the springlatch plunger is pushed in by the springlatch (see 
Section 3.3).  You can be “fooled” by this feature if you’re trying to test operate the UnLatch 
with the door open.  To do this, use a pencil or other similar object to lightly push in the 
springlatch plunger and then close the trigger wire to +V and you will see the UnLatch plungers 

move. 

 

On a service call for a unit with successful operating history, in addition to the checks mentioned 
above, check to see if the door and latch have gotten into a warped situation where there is 

heavy pre-loading on the door.  The UnLatch’s motor may not be able to release the latch under 
this condition but you should be able to hear it trying to release the latch.  The UnLatch will 
automatically shut down its motor if it can’t release the latch within 1.5 seconds.  It will operate 
normally when it is re-triggered.  You should be able to try operation by removing the pre-
loading by pushing the door closed with enough force to counteract the pre-loading.  Note that 
this situation is more likely if power supply capacity is less than 3 Amps (see Section 3.1).  

Corrections for this type of warped door situation is to have the door serviced and possibly 
increase the capacity of the power supply. 

 

If the unit still will not function, note that it does have an internal microprocessor that may have 

gone into a crash condition which may leave the unit’s gears and plungers in an unusual 
position.  This can happen sometimes if the unit is under-powered (see Section 3.1) and has 
consequently stalled (the motor is not receiving enough power to operate the latch).  While the 
motor is in the process of stalling, voltage to the processor will sharply drop and this can crash 
the microprocessor.  A crash can also occur as a random event but this is unusual.  There are 

two recovery methods that may be used to recover the unit’s operation.  The first technique is a 
simple reset achieved by cycling power to the unit.  Remove power (+V) from the unit’s red wire 
momentarily.  After power is reapplied, the unit may reset and begin normal operation.  If this 
recovery method did not work perform the second recovery method (POWER ON RESET).  
Remove power (+V) from the unit’s red wire.  Connect the unit’s red and orange wires together.  

Now reapply power (+V) to both the orange and red wires simultaneously.  This re-initializes the 
firmware and may cycle the unit to the unlocked position.  Once this operation has been 
performed, return the unit to standard wiring (orange only connects to +V to trigger the unit.) 

 

Finally, the unit could have experienced motor failure or other internal electronic failure.  It is 
repairable by the factory. 

 

PROBLEM -- Unit will occasionally not operate
Generally, this comes from too much door pre-loading possibly coupled with a low capacity 
power source.  When the UnLatch can’t generate enough torque to release the latch, it 
automatically shuts down but then operates the next time it is triggered.  See the previous 
paragraph. 

 

PROBLEM -- Latch does not re-secure when the door re-closes. 
This is not a problem with the UnLatch but is rather a problem with the installation.  The latch is 
simply not moving into position.  Make sure the door closer is properly operating to re-close the 
door with reasonable force.  Next, re-read Section 2.5 to make sure the UnLatch is in the correct 

position with respect to the door stop. 

 

PROBLEM -- Latch status sensing does not function. 
The latch status output contacts (see Section 3.3) will change state when the springlatch plunger 

is pushed in.  To check this, therefore, push the springlatch plunger lightly in with a pencil or 
other similar object.  Make sure the unit is receiving power when you make this check or the 
output contacts will not switch.  If they still do not switch, the unit will need to be returned to 
the factory for repair. 

 

PATENTS 
The UnLatch is covered under U.S. patents #5,474,342 and #6,022,056 with other US and 
international patents pending. 

Содержание Securitron UNLATCH UNL-12

Страница 1: ... operating 3 Amp input surge 12 VDC 1 5 Amp input surge 24 VDC for 100 milliseconds and 300 mA 12 VDC or 200 mA 24 VDC thereafter Operating Temperature 10 F to 125 F FIG 1 UNLATCH DIMENSIONS INCHES 4 87 1 245 3 37 4 12 3 38 1 50 1 33 RECOMMENDED TOOLS MEDIUM PHILLIPS DRIVER MEDIUM SLOTTED DRIVER CHISEL WIRE CUTTER STRIPPER VOLT OHM METER CRIMP CONNECTORS CRIMP PLIERS 2 PHYSICAL INSTALLATION 2 1 SU...

Страница 2: ...OOD FRAME MOUNTING Installation in a wood frame is straightforward It is a question of using a chisel to create a space for the UnLatch behind the existing strike The procedure depends on whether you have a 4 7 8 ANSI strike commercial or a 2 3 4 ANSI strike residential on the door In the case of a 4 7 8 ANSI strike you will be using the existing holes that mount the strike to mount the UnLatch Re...

Страница 3: ...is will avoid chiseling too big a space A tight fit is preferred as it helps the solidity of the mounting which is important if the door receives abuse Normally with a wood frame the wires will be run inside the wall Simply drill from the back of the cavity you have created rearward into the wall space to admit the wires into the walls To mount the UnLatch to the wood frame use the two furnished 1...

Страница 4: ...it card in between the door and frame To forestall this the deadlatch was created The deadlatch includes a deadlatch pin which is depressed against the flat part of the strike when the door is closed When the deadlatch pin is depressed the latch cannot be pushed in by a credit card for instance it is mechanically blocked Deadlatches therefore offer a considerably higher level of security and this ...

Страница 5: ... WHICH ALLOWS THE DEAD LATCH PIN TO COME OUT THIS UNFREEZES THE SPRING LATCH FINALLY BOTH PLUNGERS MOVE FORWARD TOGETHER THIS PUSHES OUT THE SPRINGLATCH AND DEADLATCH PIN AND THEREBY RELEASES THE DOOR Note that if the door is heavily pre loaded by someone trying to pull it open before the UnLatch has released it for example the UnLatch may not possess enough power to release the door This is terme...

Страница 6: ...onal electric strikes the UnLatch is fail secure which means that it will maintain the door in a secure position if power is lost Entry is not possible but people can of course exit by simply turning the door handle or knob from the inside FIG 7 UNLATCH WIRING WHITE STATUS COM BLUE STATUS N O CLOSURE BETWEEN V IN AND TRIGGER RELEASES LATCH ORANGE TRIGGER GREEN STATUS N C POWER SUPPLY RED V BLACK N...

Страница 7: ...re being operated from the same power supply If therefore your installation includes a digital keypad or other microprocessor equipped device make sure you have full power supply capacity or use a separate power supply for the keypad or other device 4 2 WIRE GAUGE SIZING If the power supply is some distance from the lock voltage will be lost dropped in the connecting wires so that the UnLatch will...

Страница 8: ... dead latch pin would be resting on the metal strike casing of the UnLatch In this condition if the UnLatch was allowed to operate the dead latch plunger would attempt to push the spring latch and it would be unable to do so because the dead latch pin would be pushed in by the metal casing of the UnLatch The motor would jam The UnLatch senses any motor jam condition and shuts itself down for that ...

Страница 9: ... and this can crash the microprocessor A crash can also occur as a random event but this is unusual There are two recovery methods that may be used to recover the unit s operation The first technique is a simple reset achieved by cycling power to the unit Remove power V from the unit s red wire momentarily After power is reapplied the unit may reset and begin normal operation If this recovery meth...

Страница 10: ...EMPLATE FOR CUTTING OUT ANSI 2 STRIKE PREPARATION AND INSTALLING UNLATCH ON WOODEN FRAME DOTTED LINE SHOWS AREA TO CHISEL OUT 1 3 4 DEEP FOR INSTALLATION IN WOOD FRAME 4 7 8 1 1 4 4 1 8 CENTER LINE HORIZONTAL ALIGNMENT ARROWS SEE FIG 3 ...

Отзывы: