7.  ADJUSTING SENSITIVITY 
The sensitivity pot (see Figure 1) must be adjusted for proper operation.  The setting depends 
somewhat on whether the unit is mounted on a metal or non-conducting surface.  To perform 

this adjustment, you have to start with the unit completely wired (receiving power) and 
mounted as it will be used.  NOTE: the top screw includes the spring and ring terminal 
underneath that creates the electrical connection between the plate and the sensor. 

 

Turn the timing pot all the way counter-
clockwise, the shortest time between tests of 
operation.  Re- tighten the top screw and turn 

the sensitivity pot clockwise without touching 
the plate 
until the LED just comes on.  In this 
condition, sensitivity is so high that the unit is 
on all of the time.  Slowly rotate the pot 
counter-clockwise until the LED goes out and 

then another 15 degrees counter-clockwise.  
This  is  generally  a  good  setting.    Before  re-
attaching the plate, test by touching the plate 
and observing that the LED comes on.  test with 
gloves if you expect that they will be used.  You 

may want to increase the sensitivity somewhat, 
but if you leave it just below the point where 
the LED is on all the time, you risk a condition 
where the unit will fail by being on all of the 
time. 

 

8.  TROUBLESHOOTING 
PROBLEM:  The unit will not operate when the plate is touched. 

There are three ways to know that the SP-1 is working when you touch the plate.  The LED should come 
on, you should be able to hear the relay click and the device should do what is supposed to in the 
installation (such as releasing a door).  If you get the click and LED but the unit doesn't release the door, 

check the installer wiring. 

 

If you don't get a click or LED, the sensor is not reading your touch.  Make sure you understand section 7 

on how to adjust sensitivity.  It may be set too low.  Another fault could be that the sensor itself is not 
receiving 12-24 DC power on the red and black wires.  Check the power supply and, be sure the input 

polarity is correct.  Also even if power is being applied on the red and black wires, it's possible that it's 
not getting into the sensor.  Check the connector block that plugs into the sensor circuit board for loose 

wires.  Finally, it is possible that the connection from the sensor to the plate has come loose.  Review 
Figure 1.  The ring terminal must go around the top mounting screw and the spring must be present 
around the screw. 

 

PROBLEM:  The LED remains on constantly 

First, make sure that the sensitivity is not set too high.  Review section 7.  If you can rotate the pot 
counterclockwise all the way and the unit still remains activated, the most likely cause is that the sensor 

"sees" an overwhelmingly large signal as if someone was continually touching the plate.  This will happen 
if the plate is not properly isolated from a mass of metal.  The plastic backbox achieves this isolation but it 

is possible that metal is too close to the side of the plate.  You must have one inch clearance all around.  
The same effect will occur if the plate is used outside and becomes wet.  This is an indoor product only. 

 

Certain large electronic noise sources can "swamp" the  sensor  although  this  is  rare.    Examples  would 
include large radio or radar transmitters in the building or a high voltage neon sign mounted within a few 

feet of the unit.  Call the factory if you suspect noise induced problems. 

 

PROBLEM:  The sensor is very difficult to adjust 

This is usually caused by coiling the electrical cable within the backbox.  The cable must directly exit the 

backbox through the provided hole.  Also, if the backup switch has not been installed in the side of the 
backbox, it should remain stuck down to the backbox base.  If its wires are laying up against the plate, 
this can increase sensor adjustment difficulty. 

 

Another possibility is that sometimes during handling of the product a static charge can be built up on the 
board.  Remove power at the source (not by unplugging the cable).  Turn the pot all the way 

counterclockwise.  Reapply power and adjust sensitivity as described in Section 7. 

 

9.  MAGNACARE

 LIFETIME REPLACEMENT WARRANTY 

For warranty information visit 

www.securitron.com/en/site/securitron/About/MagnaCare-Warranty 

TO ADJUSE SENSITIVITY,
ROTATE PLATE ENOUGH
TO REVEAL SENSITIVITY
POT.  RETIGHTEN TOP
SCREW HOLDING PLATE
AND THEN ADJUST POT.

 

Содержание Securitron SP-1

Страница 1: ...ew includes a spring that goes around the screw below the plate Do not lose this spring as its presence is necessary for proper operation It is not necessary to remove the top screw with the spring on it but to just loosen this screw and rotate the plate enough to access the mounting screw points Mount the unit to the wall using the supplied screws Note that there are two approaches to mounting Yo...

Страница 2: ...ne if the unit was being operated on batteries and the batteries were discharging or because of a fault in the power supply When employing the cable to make electrical connections never coil the gray cable within the white backbox It must be pulled straight out A coiled cable in the white backbox will interfere with proper electronic operation of the unit FIGURE 2 SP 1 TYPICAL WIRING CABLE RED POW...

Страница 3: ... some of the label with it When the backing has been removed you can edit the label copy by carefully removing portions of the message Use a knife tip to peel away the vinyl characters Then line up and press the label top carrier onto the plate Firmly rub all over the top carrier sheet to apply the vinyl lettering to the stainless plate and remove air bubbles Then slowly peel off the top carrier s...

Страница 4: ...e red and black wires it s possible that it s not getting into the sensor Check the connector block that plugs into the sensor circuit board for loose wires Finally it is possible that the connection from the sensor to the plate has come loose Review Figure 1 The ring terminal must go around the top mounting screw and the spring must be present around the screw PROBLEM The LED remains on constantl...

Отзывы: