Assa Abloy Securitron SAM Скачать руководство пользователя страница 8

 

 

 

 

PN# 500-10440

 

 

Page 8 

Rev. F, 02/12 

5.6.5  Soft Core Wood Door 
Use of the end brackets is recommended when installing the strike assembly on soft core wood 
style doors because a “pocketed” soft core door is not as strong in supporting the lateral forces 

applied to the strike assembly.  Use of the end brackets will provide a much more sound and 
secure anchoring platform for the installation.  Refer to Section 5.6 for use and adjustment of 
the end brackets.  Figure 11 illustrates the dimensional requirements of the cutout necessary 
for installation into wood doors using the strike end brackets. 

 

Mortise Depth

1-7/16"

[36.5]

1/8"

   

   

Strike

Idle Bracket

End Bracket

#10 x 3/4" Phillips
Flat Head Type "A"

 

Figure 11 - Wood door strike mounting with brackets 

 
5.6.6  Magnalock/Strike Installation for “B” and “D” SAM Locks 

 

***SPECIAL NOTE FOR SAM “D” MAGNALOCK (DOUBLE TRIGGER NOTIFICATION)*** 

The Magnalock mounting direction in slider doors should be considered critical for 
proper operation. 
For SAM “D” units, the Magnalock position should be installed with the cable furthest from the 
door closing face as shown in Figure 13.  This allows proper sensing of the door operation.  If 

the Magnalock direction is reversed the reed switch will be triggered by both actuator magnets in 
the face of the strike assembly.  Double triggering may cause inaccurate signals to access/alarm 
control devices attached. 

 
 

 
 
 

IMPORTANT! 

PLEASE READ AND APPLY THIS INFORMATION WHEN ALIGNING/INSTALLING THE 
LOCK AND STRIKE.  THE ALIGNMENT TOLERANCES INDICATED FOR THE SAM LOCK 

MODEL ARE CONSIDERED CRITICAL FOR THE PROPER OPERATION OF BOTH THE 

MAGNETIC BOND SENSING (MBS) AND DOOR POSITION SENSING (DPS) SYSTEMS!

 

SENSOR RANGES (PHYSICAL POSITIONING): 
The  BondSTAT “B” and DPS “D” Magnalock “Secure Zone” sensing range for the SAM lock 
model is as follows: 

 

 (The Figure 12 illustration is a visual reference to the sensing range outlined in Table A). 

Secure Sensor Indication Range 

(Dimensions from Center) 

Model 

"X" (+/-) 

"Y" (+/-) 

SAM 

5/32" [4.0]  5/64" [2.0] 

Table A 

 

Figure 12 

Содержание Securitron SAM

Страница 1: ...the door The SAM BondSTAT B Series Bond Sensor monitors the magnetic field An internal sensor activates a SPDT dry contact relay connection designed for interface to access control and or alarm system...

Страница 2: ...its Crimp Wire Connectors 3 8 Diameter X 82 Countersink Bit Crimp Tool Phillips and Standard Screwdrivers Multimeter 5 INSTALLATION INSTRUCTIONS 5 1 Pre Installation Survey It is recommended that an i...

Страница 3: ...led in a sliding door The Magnalock mounts recessed into the door frame header and the strike assembly is mounted into the top edge of the sliding door Magnalock mounted in door frame Strike mounted i...

Страница 4: ...ess of the door Divide this distance in half to locate the depth centerline of the strike assembly Using the strike assembly mounting information in Section 5 6 and the strike template provided center...

Страница 5: ...minimum depth of the cutout is noted in Figure 6 below and includes enough distance for the required recess depth of 1 16 1 6mm for the mounting brackets Install the Magnalock using the wood mounting...

Страница 6: ...the appropriate flush mounting condition and the provided shim plates may also be used to assist in further adjustment of the installation Use a hex wrench and the provided mounting screws to complete...

Страница 7: ...e solid wood doors the strike assembly may be mounted with or without the end brackets attached The door cutout requires a mortise area for the strike base assembly with sizes that are dependent on wh...

Страница 8: ...ction in slider doors should be considered critical for proper operation For SAM D units the Magnalock position should be installed with the cable furthest from the door closing face as shown in Figur...

Страница 9: ...properly functioning gap setting is achieved THE INITIAL SETTING OF THE STRIKE ADJUSTMENT SHOULDER SCREWS SHOULD BE NO MORE THAN TWO 2 TURNS OUT THIS WILL ALLOW A LARGER ADJUSTMENT RANGE TO ACCOMMODAT...

Страница 10: ...the door The door is designed with a secondary directional movement to swing open which is called breakaway Doors that are set to remain locked after the establishment has closed have the possibly of...

Страница 11: ...RED _ C NO WHT GRN ORG BLK LOCK STATUS REF SAM SERIES B BondSTAT VERSION 5 WIRE MAGNALOCK ACCESS CONTROL DEVICE LOCK STATUS _ DC POWER SUPPLY 120 VAC INPUT 12 24 VDC OUTPUT Figure 18 NC C NO REF NC RE...

Страница 12: ...ncy Manual switching or automatic triggering from a fire alarm system is practical It is the user s responsibility to correctly hookup the Magnalock according to the instructions It is recommended to...

Страница 13: ...Super Lube Aerosol with SYNCOLON PTFE Part No 31040 6oz 31110 11 oz 32015 14 oz Phone 631 567 5300 Website www super lube com APPENDIX A Troubleshooting Problem Lock Does Not Generate a Magnetic Field...

Страница 14: ...ion 2 IF PROBLEMS PERSIST CALL SECURITRON TOLL FREE 800 MAG LOCK 800 624 5625 Appendix B Wire Gauge Factoring 1 1 Remote Power Supply The Magnalock requires adequate voltage and current for proper ope...

Страница 15: ...0 Gauge 20 Gauge 18 Gauge 16 Gauge 14 Gauge 14 Gauge 12 Gauge 10 Gauge 800A 22 Gauge 22 Gauge 20 Gauge 18 Gauge 18 Gauge 16 Gauge 14 Gauge 14 Gauge 12 Gauge 600A 24 Gauge 22 Gauge 22 Gauge 20 Gauge 18...

Страница 16: ...ETIME REPLACEMENT WARRANTY For warranty information visit www securitron com en site securitron About MagnaCare Warranty PATENTS The Securitron Shear Aligning Magnalock is listed under U S patent 4 51...

Отзывы: