The serrations on the brackets are .050” [1.3mm] apart which matches the screw thread pitch 
distance that mounts the strike.  This feature will be explained during the final adjustment in 
Section 5.7.  These end brackets may also be inverted to provide for deeper mounting 

configurations.  See Figure 8 and Figure 9 for adjustable ranges and mounting methods.  
 
THE POSITION OF THE CENTERLINE OF THE STRIKE ASSEMBLY IS CRITICALLY 
RELATED TO THE CENTERLINE OF THE MAGNALOCK LOCATION. 
 

5.6.1  Hollow Metal Door (Flush Top) 
Prepare the door in accordance with Section 5.4.2
Mounting the strike assembly into a door with flush outside surfaces utilizes the same methods 
as mounting the Magnalock into a hollow metal type frame.  Figure 7 below shows a typical 
installation in a flush type aluminum door.  In this process the flush mount brackets are used to 
suspend the strike assembly into the door.  Make the necessary adjustments to the end brackets 

of the strike assembly to set the initial strike height in the door installation.  The flush mount 
brackets may be installed in either direction (see Figures 4 and 5) to set the appropriate flush 
mounting condition, and the provided shim plates may also be used to assist in further 
adjustment of the installation.  Use a hex wrench and the provided mounting screws to complete 
the installation. 

Flush Mount Bracket

(Note Orientation)

End Bracket

Idle Bracket

Strike

 

Figure 7 - Hollow frame strike assembly mounting 

 

APPLY THE PROVIDED THREAD LOCKING COMPOUND TO ALL MOUNTING SCREW 
THREADS. 

 

5.6.2  Hollow Aluminum Door (Shallow Recess Top) 
Prepare the door in accordance with Section 5.4.2
If the door has a shallow recess within the range indicated in Figure 8, a cut out area will be 
required to insert the strike assembly.  Cut out the strike mounting area using a router or saber 
saw.  The templates provided specify the dimensions of the cutouts and the locations of the 
holes for proper mounting.  In this process the flush mount brackets are not required because 

the strike can mount suspended in the door using the door edge only.  Make the necessary 
adjustments to the end brackets to set the initial strike height in the door installation.  If 
necessary, the provided shim plates may be used under the bracket mounts to create the proper 
mount distance. 

1/8" [3.2] to 1-3/8" [34.9]

Cross Section

of

Door Recess

#10 x 3/4" Phillips

Flat Head Type "A"

End Bracket

Idle Bracket

Strike

 

Figure 8 - Shallow recess door strike mounting 

 
 
 

 
 

Содержание Securitron SAM

Страница 1: ...the door The SAM BondSTAT B Series Bond Sensor monitors the magnetic field An internal sensor activates a SPDT dry contact relay connection designed for interface to access control and or alarm system...

Страница 2: ...its Crimp Wire Connectors 3 8 Diameter X 82 Countersink Bit Crimp Tool Phillips and Standard Screwdrivers Multimeter 5 INSTALLATION INSTRUCTIONS 5 1 Pre Installation Survey It is recommended that an i...

Страница 3: ...led in a sliding door The Magnalock mounts recessed into the door frame header and the strike assembly is mounted into the top edge of the sliding door Magnalock mounted in door frame Strike mounted i...

Страница 4: ...ess of the door Divide this distance in half to locate the depth centerline of the strike assembly Using the strike assembly mounting information in Section 5 6 and the strike template provided center...

Страница 5: ...minimum depth of the cutout is noted in Figure 6 below and includes enough distance for the required recess depth of 1 16 1 6mm for the mounting brackets Install the Magnalock using the wood mounting...

Страница 6: ...the appropriate flush mounting condition and the provided shim plates may also be used to assist in further adjustment of the installation Use a hex wrench and the provided mounting screws to complete...

Страница 7: ...e solid wood doors the strike assembly may be mounted with or without the end brackets attached The door cutout requires a mortise area for the strike base assembly with sizes that are dependent on wh...

Страница 8: ...ction in slider doors should be considered critical for proper operation For SAM D units the Magnalock position should be installed with the cable furthest from the door closing face as shown in Figur...

Страница 9: ...properly functioning gap setting is achieved THE INITIAL SETTING OF THE STRIKE ADJUSTMENT SHOULDER SCREWS SHOULD BE NO MORE THAN TWO 2 TURNS OUT THIS WILL ALLOW A LARGER ADJUSTMENT RANGE TO ACCOMMODAT...

Страница 10: ...the door The door is designed with a secondary directional movement to swing open which is called breakaway Doors that are set to remain locked after the establishment has closed have the possibly of...

Страница 11: ...RED _ C NO WHT GRN ORG BLK LOCK STATUS REF SAM SERIES B BondSTAT VERSION 5 WIRE MAGNALOCK ACCESS CONTROL DEVICE LOCK STATUS _ DC POWER SUPPLY 120 VAC INPUT 12 24 VDC OUTPUT Figure 18 NC C NO REF NC RE...

Страница 12: ...ncy Manual switching or automatic triggering from a fire alarm system is practical It is the user s responsibility to correctly hookup the Magnalock according to the instructions It is recommended to...

Страница 13: ...Super Lube Aerosol with SYNCOLON PTFE Part No 31040 6oz 31110 11 oz 32015 14 oz Phone 631 567 5300 Website www super lube com APPENDIX A Troubleshooting Problem Lock Does Not Generate a Magnetic Field...

Страница 14: ...ion 2 IF PROBLEMS PERSIST CALL SECURITRON TOLL FREE 800 MAG LOCK 800 624 5625 Appendix B Wire Gauge Factoring 1 1 Remote Power Supply The Magnalock requires adequate voltage and current for proper ope...

Страница 15: ...0 Gauge 20 Gauge 18 Gauge 16 Gauge 14 Gauge 14 Gauge 12 Gauge 10 Gauge 800A 22 Gauge 22 Gauge 20 Gauge 18 Gauge 18 Gauge 16 Gauge 14 Gauge 14 Gauge 12 Gauge 600A 24 Gauge 22 Gauge 22 Gauge 20 Gauge 18...

Страница 16: ...ETIME REPLACEMENT WARRANTY For warranty information visit www securitron com en site securitron About MagnaCare Warranty PATENTS The Securitron Shear Aligning Magnalock is listed under U S patent 4 51...

Отзывы: