2
of 4
Mounting
• MOUNT the Securitron EEB2
using
its included mounting device.
NOTE:
The aluminum door frame must be sufficiently routed
out to accommodate the Securitron EEB3N components.
• MOUNT the Securitron EEB3N
directly on
a narrow stile aluminum door frame.
Wiring
NOTES:
The Securitron EEB2 and EEB3N operate on 12
VDC or 24 VDC, and can accept the use of full-wave
rectified DC (transformer and bridge rectifier).
Securitron EEB2 and EEB3N are factory shipped with the jumper in
place (12 VDC). If jumper is removed, unit operates on 24 VDC.
Securitron EEB2 and EEB3N draw no current when at rest, and only
draw 28 mA at 12 VDC or 38 mA at 24VDC when releasing the lock.
1.
WIRE the Securitron EEB2 or EEB3N in
accordance with Diagram 1, 2 and 3.
CAUTION
The Securitron EEB2
and EEB3N can be damaged if
operated on 24 VDC with the
jumper in place, or operated on a
power supply different than what
is operating the magnetic lock.
Red
+12 V or + 24 V
0 V (DC Neg)
to LOCK “+” Wire
to + V
Black
Green
White
Secruitron
EEB2 or
EEB3N
Re
d
Gr
ee
n
Black
Black
Red
White
Securitron
EEB2 or
EEB3N
Device
IN +
+
–
Magnalock
Securitron
XMS
Power
Supply
Diagram 1:
Wire Identification
Diagram 2:
Typical Connection
NOTE:
Positive input voltage on the white wire must be from the
same power source that the red and black wires connected.