800-810-WIRE (9473) • www.sargentlock.com • A7857A
Keypad Programming Instructions for the Profile Series LK Lock
LK Programming (100 Users)
To determine programming steps for your lock:
• If your controller has an LK label,, use the programming below.
• If your controller has a "G1.5" label and a keypad, refer to Section 3;
• If your controller has a "G1.5" label and no keypad refer to Section 4.
• If your label has a G1-LU, G1-PK, G1-PA, G1-TU, G1-TP or G1-TA; refer to
Keypad Programming Instructions A7716 at www.sargentlock.com
Change the Master Code
99# 1234*
Yellow LED blinks
50# 1#
Yellow LED blinks
New Master Code*
Yellow LED blinks quickly
New Master Code*
Yellow LED blinks slowly
*
Yellow LED goes out (If solid, see note)
This example uses the Factory Default 1234*
It is recommended not to use the factory default master code.
To Enter the Emergency Code
99# Master Code*
Yellow LED blinks
50# 02#
Yellow LED blinks
Emergency (1-6 digits)*
Yellow LED blinks quickly
Emergency (1-6 digits)*
Yellow LED blinks slowly (If solid, see note)
*
Yellow LED goes out
Emergency Code defaults to a 10 second unlock time and will override a thrown deadbolt on a mortise lock.
To Enter or Change the Supervisor Code
99# Master Code*
Yellow LED blinks
50# 1# 03#
Yellow LED blinks
Supervisory (1-6 digits)*
Yellow LED blinks quickly
Supervisory (1-6 digits)*
Yellow LED blinks slowly (If solid, see note)
*
Yellow LED goes out
Enter A User Code
99# Master Code* or Supervisory Code*
Yellow LED blinks
50# 1# (User Number 04-100)#
Yellow LED blinks
User Code (1-6 digits)*
Yellow LED blinks quickly
User Code (1-6 digits)*
Yellow LED blinks slowly (If solid, see note)
*
Yellow LED goes out
Enter A Passage (Maintained) Code
99# Master Code*
Yellow LED blinks
50# 0# (User Number 04-100)#
Yellow LED blinks
User Code (1-6 digits)*
Yellow LED blinks quickly
User Code (1-6 digits)*
Yellow LED blinks slowly (If solid, see note)
*
Yellow LED goes out
Enter a Lock Out User Code
99# Master Code*
Yellow LED blinks
50# 3# (User Number 04-100)#
Yellow LED blinks
User Code*
Yellow LED blinks quickly
User Code*
Yellow LED blinks slowly (If solid, see note)
*
Yellow LED goes out
The “Lock Out” user is location dependent — all users above the chosen user number location are locked out of the
keypad. To ensure that all users except Master, Supervisor and Emergency are locked out, program this user at
user number location “04”.
-
+
-
+
-
+
-
+
+
-
+
-
LK