background image

A8185A

04/16

Copyright 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. 

All rights reserved. Reproduction in whole or in part without the express written  

permission of Sargent Manufacturing Company is prohibited. 

Exit Device

Installation Instructions

IN120

Summary of Contents for SARGENT IN120

Page 1: ...nt Manufacturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited Exit Device Installation Instructions IN120 ...

Page 2: ...u inférieur approuvé pour l émetteur par Industrie Canada Dans le but de réduire les risques de brouillage radioélectrique à l intention des autres utilisateurs il faut choisir le type d antenne et son gain de sorte que la puissance isotrope rayonnée équivalente p i r e ne dépasse pas l intensité nécessaire à l établissement d une communication satisfaisante Any retrofit or other field modificatio...

Page 3: ...esign setting a new standard for aesthetics and performance The IN120 uses IEEE 802 11 WiFi communication and a flexible feature set for easier more cost effective installations allowing facilities to leverage their IT infrastructure to expand access control coverage to more doors Featuring HID multiCLASS SE technology it supports heightened identity security and multiple credentials including mob...

Page 4: ...ack plastic IN 220 EM01 B IPS W Reader assembly white plastic IN 220 EM01 B CP B Reader assembly FeliCa black plastic IN 220 EM01 B CP W Reader assembly FeliCa white plastic IN 220 EM01 B CP MB xxx Reader assembly FeliCa black plastic with metal trim IN 220 EM01 B CP MW xxx Reader assembly FeliCa white plastic with metal trim IN 220 EM01 B IPS MB xxx Reader assembly black plastic with metal trim I...

Page 5: ...ilable Styles 1 3 97 4105 Exit Trim ET With Cylinder 1 97 4106 Exit Trim ET Without Cylinder 52 4845 Motor Assembly Separate not shown 1 4 68 7554 Chassis Assembly 1 68 7555 Chassis Assembly Fire Rated 68 7567 Chassis Assembly Latch Guarding 68 7569 Chassis Assembly Fire Rated Latch Guarding 5 68 4389 1 4 20 x 2 3 8 ET Screws Screw Pack E 1 6 68 2143 10 x 1 1 4 Chassis Screws Screw Pack A 1 10 24 ...

Page 6: ... Lever Reference Catalog for Available Styles 1 3 97 4107 Exit Trim ET With Cylinder 1 97 4108 Exit Trim ET Without Cylinder 52 4845 Motor Assembly Separate not shown 4 99 2401 8900 Lock Body Assembly LHR 1 99 2402 8900 Lock Body Assembly RHR 99 2403 8900 Lock Body Assembly LHR Non Beveled Door 99 2404 8900 Lock Body Assembly RHR Non Beveled Door 5 99 2628 Screw Pack 1 6 68 7550 Chassis Assembly L...

Page 7: ...commended 3 Use appropriate templates IN120 template A8214 wood and metal Exit installation instructions A6770 Note Instruction examples show wood door installation For metal doors route cables inside door Left Hand Reverse LHR Outside Inside Right Hand Reverse RHR Fig 1A Installation Instructions for 8877 8878 Rim Exit A Verify Hand and Bevel of Door 1 Door Preparation B Verify Product Label C Do...

Page 8: ...0 Exit Device Wood doors have 3 8 raceway to controller cutout and metal doors have 3 4 raceway to the controller cutout Refer to template A8214 1 Insert connector end of DPS through the raceway on the latch edge of the door Fig 2A Note For metal doors use DPS Collar 2 Push DPS firmly into place by hand IMPORTANT DO NOT TAP SWITCH WITH ANY TOOL DPS Door Position Switch Collar is used only with met...

Page 9: ...connector and two different sized ground lugs Fig 3A 1 Feed 6 pin connector and larger ground lug straight through to outside of door Fig 3A B while feeding smaller ground lug into wire hole up through wire channel and out through inside of door Fig 3C DO NOT PINCH THE WIRE HARNESS 2 Begin to secure the exit chassis with through bolts to the ET trim using 2 1 4 20 x 2 3 8 flat head machine screws ...

Page 10: ...between ET escutcheon and outside door surface A Connect motor harness adapter to chassis harness connector Fig 4A B For wood doors Route ET wire harness connector through the cylinder hole up and through the wire run channel to the controller cutout For metal doors Route ET wire harness through the cylinder hole out the controller cutout C Pass top ET trim mounting post through chassis harness gr...

Page 11: ...cure Exit Chassis 4 10 Wood Screws or 10 24 Machine Screws Inside of Door 2 12 24 x 1 7 8 Flat Head Screws Through bolts Cylinder to Chassis Fig 6 For devices without cylinder go to Step 6 Secure Exit Chassis 1 While installing the rim cylinder support the tail piece of the cylinder verifying its engagement with the top hub of the exit chassis Note Be sure ET harness is clear of cylinder and tailp...

Page 12: ...ghts reserved Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited 04 30 16 IN120 Exit Device Secure chassis cover to chassis using 4 8 32 x 5 16 oval head machine screws Fig 7 7 Install Chassis Cover Fig 7 NOTE Cable lengths exaggerated for illustrative purposes ...

Page 13: ...ion of Sargent Manufacturing Company is prohibited IN120 Exit Device 8 Outside Reader and Mounting Plate Installation Fig 8 1 Orient the reader so the LED lens is at the top 2 Feed the cable connector through the door from outside to inside 3 Install the reader to the outside of door by aligning the mounting posts with the door preparation holes Hold the reader flush against door while ensuring pr...

Page 14: ...ig 9C 4 Next feed the cables connectors through the inside mounting assembly and gasket if required 5 Insert and partially tighten 2 through bolts prior to installation of connectors NOTE Cable lengths exaggerated for illustrative purposes 9 Outside Reader Installation Continued 6 Secure ground lug with 6 32 machine screw Fig 9C Gasket is required for outdoor installations If installing with gaske...

Page 15: ...er and plate to the door Secure the following connectors to their respective terminals Fig 9A B A Secure the 4 pin DPS connector B Secure the 10 pin lock body assembly connector CAUTION Do not touch or allow debris to enter connector contacts Secure Mounting Plate IMPORTANT Do not run wires through bottom hole in plate Fig 9A B it will damage wires and the controller connector Route wires around f...

Page 16: ...f Inside Component Assembly 1 Insert top tabs of controller into slots on mounting plate Fig 10 2 Ensure proper alignment of board to board connectors while pivoting bottom of controller toward door until tab on bottom snaps securely into place on mounting plate CAUTION To avoid possible damage to board to board connectors care should be taken when securing controller to mounting plate If there is...

Page 17: ...he compartment being careful to align polarity properly 2 After batteries are installed there is a slight delay then an audible beep will sound and the lock motor will cycle Before installing batteries for the first time Remove pull tab from its position beneath the coin cell by pulling on tab in direction of arrows printed on tab Fig 11 AA Batteries 6 Coin Cell Pull Tab 13 Inside Cover Installati...

Page 18: ...on of Sargent Manufacturing Company is prohibited 04 30 16 IN120 Exit Device 1 Retrieve harness from end of rail Harness has limited travel and can be damaged 2 Attach harness to female connector on chassis 3 Install rail and screws per exit device instructions 14 Installation of Rail Assembly Fig 11 End of 8800 Rim Exit installation instruction proceed to Section 9 Operational Check at end of doc...

Page 19: ...ung 1 If using a mullion install it prior to installing hardware 2 Doors should be pre prepped recommended 3 Use appropriate templates IN120 template A8215 Field Prep Template Exit installation instructions A6705 Note Instruction examples show wood door installation For metal doors route cables inside door Left Hand Reverse LHR Outside Inside Right Hand Reverse RHR Fig 1A A Verify Hand and Bevel o...

Page 20: ...s have 3 4 raceway to the controller cutout Refer to template A8215 1 Insert connector end of DPS through the raceway on the latch edge of the door Fig 2A Note For metal doors use DPS Collar 2 Push DPS firmly into place by hand IMPORTANT DO NOT TAP SWITCH WITH ANY TOOL Wood Frame Metal Frame Dim 1 3 8 3 4 Horizontal of Strike Door Position Switch Hole Vertical of Strike Dim 2 From template Dim 1 F...

Page 21: ...ET Exit Chassis Fig 3A 1 Slide mortise lock into door and loosely secure with 2 flat head screws NOTE Exit chassis harness consists of a 6 pin female connector and ground lug Fig 3A 2 Feed 6 pin connector and larger ground lug straight through to outside of door Fig 3A B while feeding smaller ground lug into wire hole up through wire channel and out through inside of door Fig 3A DO NOT PINCH THE W...

Page 22: ... run channel to the controller cutout For metal doors Route ET wire harness through the cylinder hole out the controller cutout C Pass top ET trim mounting post through chassis harness ground lug D Ensure ET spindle engages the lower hub of the exit chassis E Begin to secure chassis to ET trim by partially tightening 2 chassis through bolts Fig 4B Do not fully tighten at this time A B C D NOTE Cab...

Page 23: ...vices without cylinder go to Step 6 1 Secure the cylinder by threading into lock body see Fig 5A 2 Verify that the key retracts latchbolt Position cylinder so that the SARGENT logo is right side up Correct Incorrect Fig 5B 5 Install Cylinder To comply with UL certifications and for security Fasten exit chassis to door using 4 10 wood screws for wood door or 4 10 24 machine screws for metal door 6 ...

Page 24: ...ghts reserved Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited 04 30 16 IN120 Exit Device Secure chassis cover to chassis using 4 8 32 x 5 16 oval head machine screws Fig 7 7 Install Chassis Cover Fig 7 NOTE Cable lengths exaggerated for illustrative purposes ...

Page 25: ...on of Sargent Manufacturing Company is prohibited IN120 Exit Device 8 Outside Reader and Mounting Plate Installation 1 Orient the reader so the LED lens is at the top 2 Feed the cable connector through the door from outside to inside 3 Install the reader to the outside of door by aligning the mounting posts with the door preparation holes Hold the reader flush against door while ensuring proper al...

Page 26: ... cables connectors through the inside mounting assembly and gasket if required 5 Insert and partially tighten 2 through bolts prior to installation of connectors NOTE Cable lengths exaggerated for illustrative purposes 8 Outside Reader Installation Continued Gasket is required for outdoor installations If installing with gasket separate gasket from mounting plate to feed cables connectors through ...

Page 27: ...der and plate to the door Secure the following connectors to their respective terminals Fig 9A B A Secure the 4 pin DPS connector B Secure the 10 pin lock body assembly connector CAUTION Do not touch or allow debris to enter connector contacts Secure Mounting Plate IMPORTANT Do not run wires through bottom hole in plate Fig 9A B it will damage wires and the controller connector Route wires around ...

Page 28: ... of controller into slots on mounting plate Fig 10 2 Ensure proper alignment of board to board connectors while pivoting bottom of controller toward door until tab on bottom snaps securely into place on mounting plate CAUTION To avoid possible damage to board to board connectors care should be taken when securing controller to mounting plate If there is resistance when securing detach controller t...

Page 29: ...n the compartment being careful to align polarity properly 2 After batteries are installed there is a slight delay then an audible beep will sound and the lock motor will cycle Before installing batteries for the first time Remove pull tab from its position beneath the coin cell by pulling on tab in direction of arrows printed on tab Fig 11 AA Batteries 6 Coin Cell Pull Tab 12 Inside Cover Install...

Page 30: ...ut express written permission of Sargent Manufacturing Company is prohibited 04 30 16 IN120 Exit Device 1 Retrieve harness from end of rail Note Harness has limited travel and can be damaged 2 Attach harness to female connector on chassis 3 Install rail and screws per exit device instructions Note This view shows rim exit device version 13 Installation of Rail Assembly Fig 13 ...

Page 31: ...ss or any other obstructions 2 Check that the key retracts the latch 3 The key should rotate freely 4 Try the inside lever ensure it retracts latch 5 Use a valid credential set up with the Lock Configuration Tool to unlock outside lever and retract latch Refer to Network and Lock Configuration Tool user manual WFMN1 for information on how to configure and program locks Twenty 20 seconds after lock...

Page 32: ...s control systems for new construction renovation and replacement applications The company s customer base includes commercial construction institutional and industrial markets Copyright 2016 Sargent Manufacturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited ASSA ABLOY ...

Reviews: