3
A7140G
Copyright ©
2010,
2020, SARGENT Manufacturing Company, an ASSA ABLOY Group
company. All rights reserved. Reproduction in whole or in part without the express
written permission of SARGENT Manufacturing Company is prohibited.
1-800-438-1951 • www.sargentlock.com
1. Prepare door and frame.
2. Mount case to door.
3a. Remove dial
from foot.
4. Connect arms, preload spring
and tighten swivel arm screw.
3b. Install separate arms.
1431 Standard Mount - H Arm Installation
(Right Hand Shown)
You’ve installed the
1431 Hold Open Closer - Standard Mount.
🛑
Go to page 7 for closer adjustments and cover installation.
RH and LH:
Index mark at 2
1st
3rd
2nd
RH:
Clockwise
to tighten.
LH: Counter
clockwise to
tighten.
1st
3rd
2nd
5. Set Hold Open.
Keep door open in position
until dial screw secures dial.
Max Door
Opening
Dim A
Dim B
120°
7-1/2"
(190.5)
13-1/4"
(336.5)
**160°
4-1/4"
(108)
10"
(254)
NOTES:
1. Select closer mounting position based on maximum door opening,
as listed.
2. For ADA applications, select 160° maximum door opening position.
3. **If butt, frame and wall conditions permit, door will open 180°.
4. Use screws provided or use mortise nuts when required. See chart
on page 2.
LH and RH:
Spring Adjustment Screw
AWAY from hinge
Dial DOWN
Left and Right Hand
1st
2nd
3rd
Rotate elbow until
Foot Assembly arm
is perpendicular to
frame.
Rotating Main arm
preloads closer
spring power.
Secure arms
with Swivel
Arm Screw.
Approved 2020-01-21