![Assa Abloy SARGENT 10X Series Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/assa-abloy/sargent-10x-series/sargent-10x-series_installation-instructions-manual_2988436002.webp)
2
Copyright © 2021 SARGENT Manufacturing Company. All rights reserved. Reproduction in whole or in
part without the express written permission of SARGENT Manufacturing Company is prohibited.
1-800-727-5477 • www.sargentlock.com
A8286 04/21
10X Line
Installation Instructions
Cylindrical Lockset
5
Adjust Lock for Door Thickness (if necessary)
6
Install Outside Assembly
To adjust lock to door thickness if other than 1-3/4”
(44mm) refer to Section 5.
Insert lockbody into door from outside making sure that
lockbody hooks latch case and retractor engages bolt
tail(s). See Figure 6.
DO NOT FORCE. (If lockbody does not engage latch easily,
check door preparation for errors.)
Latch bolt tail should be centered in depth of retractor. If
it is not, refer to Section 5 to properly adjust the lock for
door thicknesss.
Lock is factory preset for 1-3/4" (44mm) doors unless specified. To adjust
lock to door thickness if other than 1-3/4" (44mm):
1. Remove trim assembly from the lockbody. (See Figure 5).
2. Rotate mounting plate to adjust for proper door thickness.
•
For 2" thick door the inside face of the mounting plate should be
flush with the face of the bearing. (See 5a).
•
Verify correct position from the markings on the through-bolt
stud, or by measuring from inside surface of the mounting plate to
the centerline of the retractor (See 5b).
3. Reassemble the outside trim assembly to the lockbody.
4
Latch Installation
Install screws (2) #8-32 x 3/4".
Figure 4
Spin the mounting plate to the left to
adjust for larger door thickness.
Figure 6
Trim Assembly
Figure 5
Figure 5a
Door Thickness
Dimension A
1-3/4
" (44 mm)
7/8
" (22 mm)
2
" (50 mm)
1
" (25 mm)
2-1/4
" (57 mm)
1-1/8
" (29 mm)
Figure 5b
Centerline
of retractor
Retractor
Dimension A
Bearing
These
surfaces
flush
Mounting Plate