Model 93,
Metal Frame
Figure 11
6-32 FHPMS
(6 places)
1/4-20 x 5/8 FHPMS
(4 places)
Frame Rabbet
G. Install closer.
1. Install closer in prepped frame with
four (4) 1/4-20 x 5/8" FHPMS mounting
screws provided. (Figure 12)
NOTE: Mounting plate should be flush
with frame rabbet.
H. Install cover plate.
1. Install cover plate to closer mounting
plate with six (6) 6-32 x FHPMS
mounting screws provided. (Figure 13)
Figure 12
OR
F. Install track to door.
1. Make sure slider and track components are
installed prior to installing track to door.
2. Install track and, if necessary, optional
retrofit spacer (replacement application
only, consult factory) using either four (4)
provided 1/4-20 x 7/16" FHPMS screws
for metal door or four (4) provided #14
x 1-1/4" FHPWS screws for wood door.
(Figure 11)
Figure 13
Installation