Assa Abloy Profile S2-IA Скачать руководство пользователя страница 7

S2 80 Series Exit Devices

Profile Series v.S2

90669:D 8/01/2013

  

Copyright © 2003, 2004, 2007-2013, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. 

Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibite

d.

5

1-800-727-5477 • www.sargentlock.com

The Profile Series v.S2 products for the SARGENT Rim and Mortise Exit Devices provide networked access control in areas where life-safety is a primary 

concern. This includes stairwell areas or tenant-occupied facilities.

Inside

9" 

(228mm)

Outside

8-3/4"  

(222mm)

3-3⁄4" 

(95mm)

1-13⁄16" 

(46mm)

Outside ET Lever Control 

•   Cast  escutcheon
•   Projection   

13/16" (21mm)

•   For Rim Exit  

Devices: 

777-8 (cylinder hole) 

778-8 (no cylinder hole)

•   For Mortise Exit  

Devices: 

777 (cylinder hole) 

778 (no cylinder hole)

8-1/16" 

(205mm)

ETL Shown

Mechanical Features

•  Certified ANSI/BHMA A156.3 Grade 1
•  UL/ULC Listed for fire doors*
•  FCC certified
•  Windstorm & Florida Building Code information is listed on page 16
•  Motor-driven ET trim
•  Latch 3/4" (19mm) throw (stainless steel 8800, anti-friction brass 8900)
•  For 1-3/4" (44mm) door standard. Consult factory for other thicknesses
•  Batteries included 

Proximity Only 

Shown

3-3/4" 

(95mm)

Escutcheons

•   Zinc die cast
•   Projection at top  

1-5/8" (41mm)

•   Operating temperature –  

125 kHz proximity products:  

-40° F (-40°C) to 135° F (57°C)

    13.56 MHz iCLASS products:  

    -13°F (-25°C) to 151°F (66°C)
•  LEDs indicate valid/invalid entries
•   Keys/buttons with double shot  

mold construction prevents wear

52-3893 Door Position Switch (DPS) 

(included)

•  SPDT concealed switch (2 wire)
•  Metal Door adapter included
•  3/8" Diameter for wood door
•  3/4" Diameter for metal door
•  Supplied with v.S2 Exit Devices

All S2 Exit Devices feature:

•  Always allows free egress
•  Key outside retracts latch (8877 and 8977)
•   Outside lever rigid except when in passage  

mode or valid user code entered

•   Door Position Switch (DPS, P/N 52-3893)  

supplied

Note: The DPS is installed right above the lock  

and connects directly into the lock’s electronics  

Cylinder Override features:
•   Cylinder override for 8877 is a 34 rim cylinder;  

for 8977 is a 46 Mortise cylinder (1-3/4" length)

17-3/8"

(441mm)

17"

(431mm)

17-3/8"

(441mm)

17"

(431mm)

S2-8900 Mortise 

Exit Devices

S2-8800 Rim 

Exit Devices

Options Series Technology Type Function

Rail Size

ET Trim/Lever

Finish

Hand

Door Width

Select from

pages 13-15

Select from S2 Exit Device  

Function chart above

E:  24  -  32";  F:  33  -  36";                

J: 37 - 42";   G: 43 - 48"

ET followed by lever 

designation from  

pages 6 & 7

Select from 

pages 6-8

RHR or  

LHR

If supplied,  

rails will be  

cut to size

Example:

S2-PK-8878

F

ETL

10B

RHR

36"

Mortise Lock Exit

Rim Exit

If the lock needs to have:

Then select:

Then select:

Series

Technology

Type

Function

Series

Technology

Type

Function

Prox and keypad
Key override

S2 

PK

89

77

S2 

PK

 88

 77

No key override

S2

PK

89

78

S2

PK

88

78

Prox only
Key override

S2

PA

89

77

S2

PA

88

77

No Key override

S2

PA

89

78

S2

PA

88

78

iCLASS and keypad
Key override

S2 

IK

89

77

S2 

IK

 88

 77

No key override

S2

IK

89

78

S2

IK

88

78

iCLASS only
Key override

S2

IA

89

77

S2

IA

88

77

No Key override

S2

IA

89

78

S2

IA

88

78

* Any retrofit or other field modification to a fire rated opening can potentially impact the fire  
rating of the opening, and Sargent Manufacturing Company makes no representations or  
warranties concerning what such impact may be in any specific situation. When retrofitting any 
portion of an existing fire rated opening, or specifying and installing a new fire-rated opening, 
please consult with a code specialist or local code official (Authority Having Jurisdiction) to 
ensure compliance with all applicable codes and ratings.

FOR 

TRAINING 

PURPOSES 

ONLY 

DATED 

MATERIAL

Содержание Profile S2-IA

Страница 1: ...production in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited Profile Series v S2 Available through Authorized Channel Partners only Contact your...

Страница 2: ...ver based antimicrobial compound from Agion Technologies As an integral part of the finish coating MicroShield lasts for the life of the hardware MicroShield coating permanently suppresses the growth...

Страница 3: ...service products The Certified Integrator CI program provides hands on training for security systems integrators and network administrators Not only does this training familiarize certified integrato...

Страница 4: ...override Proximity Credentials Supports all HID 125 kHz proximity formats up to 39 bits including Corporate 1000 Also available with keypad option PK for two factor authentication iCLASS Credentials...

Страница 5: ...no key override S2 82 279 PA If the lock needs to have Then select Series Type Function Technology iCLASS and keypad Key override and deadbolt S2 82 276 IK Key override and no deadbolt S2 82 278 IK De...

Страница 6: ...nd connects directly into the lock s electronics v S2 Cylindrical Lock Functions If the lock needs to have Then select Series Type Function Technology Prox and keypad Key override S2 10 G77 PK Prox on...

Страница 7: ...ide retracts latch 8877 and 8977 Outside lever rigid except when in passage mode or valid user code entered Door Position Switch DPS P N 52 3893 supplied Note The DPS is installed right above the lock...

Страница 8: ...products Please reference the chart below for finishes available Standard and Coastal Levers Handing Left Hand Door LH Outside Right Hand Door RH Outside Right Hand Reverse Door Outside RHR LHR Outsi...

Страница 9: ...ntact factory for current lead times Studio Collection Levers are available with the 8200 Series Mortise Locks With Exit Devices the Studio Collection is available with the ET trim creating uniformity...

Страница 10: ...ofile Series v S2 Series Exit Devices with Gramercy Levers Gramercy Series Levers REM RGM RCM RAG RAL RAM RAS RAW Lever Designation Lever Description Available Finishes AS ORDERED RAG Grooved Insert 2...

Страница 11: ...ss infrastructure Lock Management Tool is a program that allows an administrator to establish multiple user types time zones holidays user groups auto unlock periods and to obtain transaction history...

Страница 12: ...adhesive backing which allows it to be secured to any non metallic object Easily Secured To Employee badges PDAs Magnetic stripe cards Cell phones 26 Bit Format HID Coded Wiegand Output 125kHz Gray co...

Страница 13: ...l 3267 Remote Power supply module 52 0258 Cable Assembly Power Supply to Power Transfer 12 3 6m shielded cable 52 2498 9VDC 700 ma Power Supply circuit board Replacement circuit board assembly 52 3852...

Страница 14: ...d exterior applications only Included with product 82 0500 For use with 8200 Mortise Escutcheon 68 1400 For use with 8800 or 8900 Exit Escutcheon Weatherseal Gasketing 52 0263 For use with ET Trim 10...

Страница 15: ...only Strike Options 23 4 7 8 124mm ANSI flat lip strike 8900 mortise lock exit device mortise locks only 28 4 7 8 Strike 808 Lip length 1 1 4 10 line only OBS Open Back Strike for 82278 82279 only WBS...

Страница 16: ...73 7P Hardware provided to accept XC Uncombinated 7 Pin SFIC Permanent Core Packed Loose 10 Line J lever not available Construction Key Systems 21 SARGENT Lost Ball Construction Keying for Conventiona...

Страница 17: ...so F1 Security Removable Core cylinder Not available with 10 Line Patented 84 Hardware provided with SARGENT Keso Construction Cores Not available with 10 Line Permanent Cores ordered separately Cylin...

Страница 18: ...esting Application Standard TAS 201 1994 Testing Application Standard TAS 202 1994 Testing Application Standard TAS 203 1994 published in the Florida Building Code UL Certification Directory ZHEM R217...

Страница 19: ...Provide access control products with non volatile memory 4 Provide keypad proximity S2 PK proximity only S2 PA keypad iCLASS S2 IK and iCLASS only S2 IA locks with a minimum of 2 400 user codes and th...

Страница 20: ...ns The company s customer base includes commercial construction institutional and industrial markets Copyright 2003 2004 2007 2013 Sargent Manufacturing Company an ASSA ABLOY Group company All rights...

Отзывы: