Assa Abloy Premium Plus HSA6410 Скачать руководство пользователя страница 8

8

23. Date/Time? / Next step

   Select date/time? To go back to step 22. 

Select next step to progress.

24. Start walk test  (OK?)

   Follow the on-screen instructions to test all the 

learnt-in devices except the siren.

• Press the test buttons on the PIR and door contact 

and the arm keys on the keyfob and keypad to 
send a test signal.

• The walk test can be quit at any time by pressing 

the 

X

 key. 

• Walk test is used to check that the sensors are 

working correctly.  Walk test can also be used 
to find out if the devices are in radio range of the 
control panel.

• The control panel will chime and display the device 

that sent the test signal.

25. Test device ? / Next step

   To re-test press the 

p

 key and 

3

, otherwise 

press 

3

 directly to go to the next step.

26. Setup finished (OK?)

   Press 

3

 and “

Start again?

” will be shown, to 

restart press the 

p

 key and 

3

, otherwise 

press 

3

 directly to go to finish.

• The control panel will display “

Alarm off

” with the 

time and date.

• More advanced programming, such as adding 

contactless tags, device naming, entry/exit times, 
adding other users and any corrections can be 
made in the main programming menu, see section 
5 Control Panel Menu System in Detail.

• All the devices are set-up as burgular mode. This 

will result in the siren ringing instantly when you 
enter the house (no countdown). You need to setup 
an entry device if you want a countdown period. 
See Edit device on page 13. 

Steps continued...

Содержание Premium Plus HSA6410

Страница 1: ...rised tampering with these items will result in an alarm This feature can be turned off by the user when a battery change is required Take care of your safety Display extreme caution when using ladders or steps please follow manufacturer s instructions Be careful when using hand and power tools and follow the manufacturer s guidelines when using them Take care that the correct tools are used Wear ...

Страница 2: ...es ensure that any tamper switches close fully On uneven surfaces it may be necessary to place packing behind the switch for reliable operation Extend The System Extend the system in the future to increase your security or as your needs change For example add extra PIR motion detectors and extra door window contacts 1Work out the best places to locate the devices for maximum protection Having chos...

Страница 3: ...9 0 3def Yale R pr 1 2abc 4ghi 5jkl 6mno pqrs 7 8tuv wxyz 9 0 3def Yale PIR motion detector Mount in a position such that an intruder would normally move across the PIRs field of view Height should be between 1 7 and 2 3 metres above floor level Location in a corner will ensure wider room coverage Do not mount the PIR where its field of view will be obstructed e g by curtains ornaments etc Do not ...

Страница 4: ...wer LED Add Device Numeric Text Keypad Back Space OK Fault LED Control panel A power adaptor is supplied that plugs into mains supply wall socket and control panel Do not plug in at this stage this will be done at First Time Easy Install section 3 In addition to the adapter there is a rechargeable battery inside the control panel that serves as a backup in case of a power failure A fully charged b...

Страница 5: ... the battery cover insert the 23A MN21 battery as shown and replace battery cover Switch to on Help button accessory Remove the cover by loosening the fixing screw and insert the 12V battery supplied as shown Please ensure you observe battery polarity Tamper switch Jumper switch Tamper switch Jumper switch Magnet Extension terminals Learn Test button Learn Test button On Off switch Door window con...

Страница 6: ...ong number Make a note of the entered code it will be required later 3 Set 2nd code Y N Select No to skip Yes to enter 2nd code Maximum 3 set of codes can be set The current selection is shown by the flashing dot on the far LEFT Use p q keys to navigate 4 Reset code Next step Select reset code to repeat step 2 or next step to proceed Cursor is on NEXT STEP as default 5 Add Device OK Press 3 6 Push...

Страница 7: ...st call You can choose to test the telephone message calling feature with the Yes No option To make a test call plug in the telephone line cord supplied into the control panel as shown Find a convenient telephone line wall socket and plug the other end of the cord in Follow the on screen instructions to complete the test Check with the called party before doing the test Four messages will be playe...

Страница 8: ...that sent the test signal 25 Test device Next step To re test press the p key and 3 otherwise press 3 directly to go to the next step 26 Setup finished OK Press 3 and Start again will be shown to restart press the p key and 3 otherwise press 3 directly to go to finish The control panel will display Alarm off with the time and date More advanced programming such as adding contactless tags device na...

Страница 9: ...ing is described more fully in Control Panel Menu System in Detail in section 5 The siren tamper will now be disabled for 1 hour after which it will automatically arm again If longer is needed to fit the siren then simply repeat the steps above Leave the control panel in programming mode to stop the system responding to tampers If the control panel automatically times out re enter programming mode...

Страница 10: ...ack together and tighten bottom screw the PIR installation is complete Before proceeding to mount the devices physically check that the control panel will receive the system radio transmissions by doing a simple radio range test Put the control panel into walk test mode KEYPAD press the arm button HELP BUTTON press the button ALL OTHER DEVICES Hold the device in the desired location and press the ...

Страница 11: ...similar way to doors Make sure the tamper switch spring is fully depressed Mounting using adhesive pads 1 Clean the mounting surface with a suitable degreaser agent 2 Remove the protective film from one side of the adhesive pad and apply to the back of the sensor and magnet Remove the remaining protective film and firmly press into place 3 Test sensor by pressing the test button and opening and cl...

Страница 12: ...ownwards If the lowest position is reached the down arrow symbol q disappears If an up arrow symbol p appears on the last column of the screen it indicated the selection list can be scrolled upwards If the highest position is reached the up arrow symbol p disappears Selecting X will return to the Alarm Off screen Important Note In programming mode if no key is pressed within 5 minutes the control ...

Страница 13: ...evice is triggered when the system is either away or home armed it will start an entry delay period to give enough time to disarm the system If the delay period expires without being disarmed the control panel will respond with a burglar alarm If the device has been set to entry and triggered when the system is in disarmed mode the control panel will make a ding dong door chime sound if the door c...

Страница 14: ... If a device name has not been programmed the screen will show the preset zone number instead Program Siren If an outdoor siren is to be included in the system this should be programmed in to the control panel To program the siren select program siren in the device menu The following items are available in this menu Learn Siren Siren Tamp On Siren Tamp Off Confirm On Confirm Off Entry Snd On Entry...

Страница 15: ...n Code then press 3 a list of 4 PIN codes will be shown occupied codes are shown with The list can be scrolled up and down using thest keys 2 Select the code you want to change and press 3 enter your new PIN code and press 3 3 You will be asked to repeat the PIN code enter it again and confirm by pressing 3 the new code is now programmed X can be used to correct entry errors pressing X repeatedly ...

Страница 16: ...s an entry timer is activated Options available are RC Ent E On and RC Ent E Off RC Ent E Off is set as factory default Mobility CHK Mobility check allows remote monitoring of the sick or infirm if there is no movement around the house for a preset period of time an emergency alarm will be activated and reported over the telephone line This feature operates by having a preset timer that is reset b...

Страница 17: ...ontrol panel will now display call progress The address message and pre recorded emergency burglar and acknowledgement request messages will be played in a loop for 85 seconds The test can be cancelled at any time by either pressing the X button or the call recipient pressing 9 on their phone to acknowledge the call If a radio DECT or mobile phone is used remember to press 9 repeatedly until the c...

Страница 18: ...ly will only disarm the system during entry time after an entry or away entry door window contact or PIR has been triggered 2 The control panel will sound a long beep The siren will beep twice and the strobe will flash side to side Alarm off will be displayed on the screen and the system is now disarmed Home Arm The home mode allows the home to be partially armed so that no one can get inside with...

Страница 19: ...et phone numbers After dialling the control panel will wait 5 seconds then playback the messages in a loop It will first play the recorded address message then the pre recorded messages Burglar Emergency depending on the nature of the alarm and finally an acknowledgement request message The recipient should acknowledge the message by pressing 9 on their telephone when prompted Recipients using rad...

Страница 20: ...y entry sensor is activated in the entry period Keypad Keypad code changing and setting The keypad code is separate from the user codes and is used to access the keypad test programming mode This will need to be changed to preserve security The keypad has two operational modes PIN code and command The keypad needs to be set to the PIN code mode to be compatible with the control panel 1 Press the A...

Страница 21: ...l repeat the local fire alarm with a radio fire alarm signal to the control panel Testing Smoke detector testing should be done on a regular monthly basis Pressing the test button will make the LED flash the audible sounder chime and will send a radio test signal to the control panel when the button is released If nothing happens after pressing the test button it indicates the batteries will need ...

Страница 22: ...d disarmed take care not to confuse the two different conditions PIR battery change When the battery is low the LED will flash when any movement is detected The batteries are changed as follows 1 Put control panel into programming mode to prevent a tamper alarm 2 Loosen the case screw and remove PIR sensor from base to reveal three AAA batteries 3 Insert new alkaline batteries observing correct po...

Страница 23: ...s If the LED lights the new battery installation is successful screw keypad back on and the battery change is complete Panic button battery change When the battery is low the LED will glow dimly when the button is pressed The battery is changed as follows 1 Loosen the bottom case screw and take button cover off base 2 Insert new 12V 23A MN21 alkaline miniature lighter battery taking care to observ...

Страница 24: ...IR has sophisticated false alarm filtering that will filter out random fluctuations and responds to genuine movement across field of view it is less sensitive walking directly towards it PIR gives false alarms Check pets have no access to protected area Check that PIR is not pointed at sources of heat or moving objects e g fluttering curtains Check that PIR is not mounted above convector heaters o...

Страница 25: ...e than one fault is present then individual fault messages will be displayed sequentially at 2 second intervals _____________________________________________ Reset Procedure Reset to factory default setting The control panel can clear all programmed parameters by the following sequence 1 Power down control panel and remove the battery 2 Apply power while holding down the p key 3 Release the p key ...

Страница 26: ...92MHz AM transmitter Power supply 4 5V 3 x AAA alkaline cells 2 years typical domestic service life 1 minute sleep timer Movement detection range 15m 110 Door window contact Radio Microprocessor controlled 433 92MHz AM transmitter Power supply 3V CR2032 lithium coin cell 2 years typical domestic service life Smoke detector Radio Microprocessor controlled 433 92MHz AM transmitter Power supply 6V 4 ...

Страница 27: ...insert the product details www yale co uk product registration Customer Service At Yale we know the importance of providing security products that are easy to install and use However should you have any questions or experience a problem with your purchase please visit www yale co uk help Information ...

Страница 28: ...onstruction and RF environment Radio Microprocessor controlled 433 92MHz AM transmitter Power supply 12V 23A MN21 alkaline miniature lighter battery 3 years typical domestic service life 0560 18 All devices E MC Tested to ETS 300 683 Radio Components tested to EN 300 220 1 E nvironmental conditions 10 C to 40 C relative humidity 70 non condensing for all units except the external siren Siren 20 C ...

Отзывы: