Assa Abloy InControl 3270 Скачать руководство пользователя страница 3

InControl 3270 and ToConnect 3270

Incedo™ Open Quick Start Brochure 1.0

3

Connecting 24 V Electric Strike

1) 

Follow step 1) from 

Connecting 12 V Electric Strike

.

2) 

Connect the electric strike.  

Configure the relay to passive mode and supply 24 V from 

the board. Configure the electric strike for NO (fail-secure) 

or NC (fail-safe) mode, and mount a flyback diode between 

the + and C/0 V/GND terminals. 

Jumper setting

Relay output mode

Passive mode: RE1 or RE2 connectors NC, NO, and C 

directly connected to the relay.

3) 

Make the connections.

Terminal

Electric strike

NO or NC

+ (NO or NC)

0 V

C/0 V/GND

Terminal T1

Terminal T2

C

DC IN 24 V

4) 

Follow step 3) from 

Connecting 12 V Electric Strike

.

 

 

 

 Adding Hi-O Devices

Mode selection DIP (A),  +12 V DC (B),  from controller unit.

1) 

Locate terminal block T2.

2) 

Connect the Hi-O bus device to the controller unit.

Terminal T2

Connect to

Hi-O H

H terminal on the Hi-O device or bus.

Hi-O L

L terminal on the Hi-O device or bus.

DC OUT 0 V

0 V/ground terminal on the Hi-O device or bus.

DC OUT 12 V

Optional. +12 V on the Hi-O device or bus.

3) 

If externally powered, power up the Hi-O device.

4) 

Optional: Test the Hi-O device before pairing. 

a)  Power up the controller unit. 

b)  Test the device on the bus. 

c)  Disconnect the unit from the power supply.

5) 

To pair the Hi-O device with the controller unit, set the 

Mode selection DIP switch 1 to ON. 

Mode selection DIP

Function

DIP1 = ON: Hi-O pairing mode at power-up

6) 

Optional: Select the desired electric lock failsafe and fail 

secure modes at power failures.

Mode selection DIP

Function

DIP2 = ON: Motor lock door monitor (Hi-O) is 

deactivated.
DIP2= OFF: Default. Motor lock door monitor 

(Hi-O) is activated.
DIP3 = ON: Failsafe for electric strikes.  

Unpowered strikes are unlocked.
DIP3 = OFF: Fail secure for electric strikes.  

Unpowered strikes remain locked.

7) 

Ensure that the bus is properly terminated.

8) 

Power up the controller unit. 

LED D15 (blue, Service status) is steadily lit during the Hi-O 

pairing process. When LED D15 blinks, and LED D7 (yellow, 

DC overload) blinks fast, the pairing process is complete.

9) 

Reset the Mode selection DIP.

Mode selection DIP

Function

DIP1 = OFF: Normal operational mode.

 

The Mode selection DIP must be reset before the controller 

unit reboots after 20 seconds. After reboot, LED D8 (red, 

Hi-O encrypted) should be on. If LED D9 (green, Hi-O un-

locked) is on, the pairing process failed.

10) 

Power cycle the controller unit.

Removing Hi-O Devices

1) 

If externally powered, turn the Hi-O device on.

2) 

Set the Mode selection DIP switch 1 to ON. 

DIP2 and DIP3 are not used while unpairing the Hi-O bus.

3) 

Press and hold the tamper switch.

4) 

Power up the controller unit. 

When LED D15 blinks, and LED D7 blinks fast, the unpairing 

process is complete. 

5) 

When the unpairing process is complete, release the tam-

per switch.

6) 

Power off the controller unit.

7) 

Disconnect, add, or remove the Hi-O device from the bus. 

The removed device can now be used with other controller 

units.

8) 

To pair the Hi-O bus, follow 

Adding Hi-O Devices

 from step 3.

 

C

+

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

1

2

3

4

5

6

ON

Note!

 

During the Hi-O pairing process, exit buttons cannot 

be used to open the door.

1

2

3

4

5

6

ON

6 5 4 3 2 1

ON

T2

OV

L

0V

24V

H

DC OUT

Hi-O

DC IN

12V

H

L 12 V 0 V

A

 

B

 

T1

+24 V

GND

NC
C

NO

OV

C

+

L

0V

24V

IN1

NC NO

RE1

RE2

C

NC NO

CL- CL+

C

IN2

IN3

GND

GND

GND

RE2

RE1

H

DC OUT

Hi-O

DC IN

12V

T2

Note!

 

Ensure that the specifications are not exceeded. 

 

The maximum load is 1 A at 28 V DC.

1

2

3

4

5

6

ON