InControl 3270 and ToConnect 3270
Incedo™ Open Quick Start Brochure 1.0
2
Installing Controller Unit
The supplied housing have room for one add-on card.
It is secured to the wall using four 5mm screws (not included).
Cables can either be run from a hole in the wall or from the
sides. Before mounting, consider placement with respect to
cabling needs and exposure to wear and damage.
1)
Secure the back cover to the wall, with the part marked UP
facing upwards.
2)
Optional: Install an additional relay board.
3)
For the selected components and interfaces, make the
desired cable connections.
4)
Connect the power supply, and power up the unit.
If powering from PoE+, connect the network cable.
5)
Connect the controller unit to the local network.
A number of LEDs on the controller unit should light up.
6)
Ensure that the tamper spring (A) is secured to the tamper
switch (B). It should fit tightly around the button.
7)
Close the front cover and secure it with the two screws.
Connecting Controller Unit
A)
Network router or switch
B)
RJ-45 Ethernet connector PoE+
C)
RJ-45 Ethernet connector (no PoE)
1)
To connect a Controller to the cloud service:
Controller
Connect to
RJ-45 PoE*
Local network router or switch with Internet access.
2)
To connect a Door Controller to the parent Controller:
Door controller
Connect to
RJ-45 PoE*
•
The parent controller’s local network switch.
•
Optional: The parent controller’s free RJ-45
connector (no PoE).
* Power over Ethernet (PoE) is optional. It is recommended to
power controller units from DC IN.
Connecting 12 V Electric Strike
Optional dual loop (A), door sensor (B), flyback diode (C).
1)
Select input and relay.
An additional relay board can also be used.
Function
Quantity
I/O
Electric strike
1
RE1-2 Relay board: RE3-RE8
Door sensor
0-1
IN1-IN3 Relay board: IN4-IN7
2)
Connect the electric strike.
Configure the relay to supply 12 V. Configure the electric
strike for NO (fail-secure) or NC (fail-safe) operation. Mount
a flyback diode between the + and C/0 V/GND terminals.
Jumper setting
Relay output mode
Powered mode: RE1 or RE2 connector NC or NO
su12 V DC C connected to ground.
Make the connections.
Terminal T1
Electric strike
NO or NC
+ (NO or NC)
C
C/0 V/GND
3)
Optional: Connect the door sensor.
Mount the input as dual loop in the web application and
connect dual loop resistors in the switch.
Make the connections.
Terminal T1
Electric strike
IN
NC
GND
0 V/C
C
–
+
Note!
The LEDs on the PCB are turned off when the lid is
closed properly, with the tamper spring in correct
position.
Note!
When running a network cable, the bending radius
must be 3 cm or larger. Category 5e, or higher,
twisted-pair cable is recommended.
Ethernet/PoE
B
C
> 3 cm
A
T1
+12 V
GND
NC
C
NO
C
–
+
IN1
NC NO
RE1
RE2
C
NC NO
CL- CL+
C
IN2
IN3
GND
GND
GND
RE2
RE1
R2
R1
IN1
NC NO
RE1
RE2
C
NC NO
CL- CL+
C
IN2
IN3
GND
GND
GND
IN1
NC NO
RE1
RE2
C
NC NO
CL- CL+
C
IN2
IN3
GND
GND
GND
C
B
A
148,1 mm
126,1
144
5 mm