3085006.002 Rev. 3
6
3. Installing the Lock
1. SLIDE lock into cutout.
NOTE:
(Optional) Install RS485 termination jumper (KS210).
(Optional) The DPS signal is closed when the handle is
resting in its locked position. The DPS circuit can be
extended to include normally open DPS switches
arranged in a series to monitor additional doors and
panels.
DPS Extension Cable
DPS
Switches
(SPST-
NO): As
Needed
Switch #1
(SPST-NO):
Provided
2. PERFORM the following to
extend the DPS Circuit.
a. REMOVE the DPS jumper.
b. CONNECT the included
DPS extension cable.
c. CONNECT additional
normally-open DPS
switches as shown to
monitor additional panels.
3. CONNECT the female, 10-position Hirose
™
connector on the lock side interface cable
to the KS200.
4. ENSURE the lock side interface cable will
properly protrude from the bottom of the
KS200
prior to attaching the rear bracket. ENSURE
the wiring is not obstructing the mounting
holes prior to securing the rear bracket.