3085006.002 Rev. 3 

Package Contents

Recommended Tools

Approved RFID Credential 
Phillips P2 driver 
WT-2 Wiegand Test Box 

Optional Additional Tools: 
SFIC Core for key override or 
SFIC Blank Plastic Core 

Normally Open DPS Switches 
System Side Interface Cable 

Specifications

Voltage:

  12–24V DC ±10% (Power Supply not provided) 

KS200 / KS210 Current Consumption: 

Model 

KS200 / KS210 

Input Voltage (V DC) 

12V DC 

24V DC 

Current 
     Standby Avg.

1

50 mA 

40 mA 

     Max Avg.

2

100 mA 

75 mA 

     Peak

3

130 mA 

130 mA 

1 Standby AVG – RMS current draw without a card in the RF field with both LEDs active. 
2 Maximum AVG – RMS current draw during continuous card reads, and both LEDs active. 
3 Peak – Highest instantaneous current draw during RF Communication, in-rush, or unlock cycles 

Handling Selectors 

Lock  

Handle 

Mounting Plate 

Mounting Screws  

Cam 

DPS Cable 

SFIC Cam  

Lock Side 
Interface Cable 

Содержание HES KS200-640

Страница 1: ...3085006 002 Rev 3 1 HES Inc Phoenix AZ 1 800 626 7590 www hesinnovations com KS200 640 KS210 640 Server Cabinet Lock Series Installation Instructions...

Страница 2: ...0 KS210 Current Consumption Model KS200 KS210 Input Voltage V DC 12V DC 24V DC Current Standby Avg 1 50 mA 40 mA Max Avg 2 100 mA 75 mA Peak3 130 mA 130 mA 1 Standby AVG RMS current draw without a car...

Страница 3: ...3085006 002 Rev 3 3 Operating Temperature 10C to 50C Holding Force 250 lbs...

Страница 4: ...iCLASS SEOS iCLASS SE ISO 15693 ICLASS ISO 14443A Mifare Mifare Plus Desfire SE Desfire EV1 EV2 NFC BLE NOTE Contact HID Global Technical Support at 1 866 607 7339 for additional configuration cards...

Страница 5: ...ent 6 or 7 pin SFIC cores 2 Preparing the Cabinet 1 LOCATE the 1 25 mm x 6 150 mm lock cutout on the door some doors may require modification 2 ENSURE power is available at the rack 3 RE USE the exist...

Страница 6: ...es SPST NO As Needed Switch 1 SPST NO Provided 2 PERFORM the following to extend the DPS Circuit a REMOVE the DPS jumper b CONNECT the included DPS extension cable c CONNECT additional normally open D...

Страница 7: ...that the lock is fully secured and flush to the mounting surface in order to depress tamper switch on back of device for correct operation NOTE If the tamper switch is not fully depressed the lock op...

Страница 8: ...1 Black 2 White 3 N A 4 N A 5 Red 6 Green 7 Orange 8 Brown 1 Gray 2 Yellow 3 Violet 4 Blue Function 12 VDC Reader Wiegand Data N A N A 12 VDC Reader Wiegand Data LED 12 24 VDC Lock Tamper DPS 12 24 V...

Страница 9: ...ires for Wiegand may be reused for OSDP However standard Wiegand cable may not meet RS485 twisted pair recommendations for maximum data transmission speed and distance Note For OSDP cable lengths grea...

Страница 10: ...3085006 002 Rev 3 10 Connector and Cable Diagram...

Страница 11: ...3085006 002 Rev 3 11 Server Cabinet Wiring Example...

Страница 12: ...esting the Lock with the Access Control System 1 TEST the lock with a known good credential to confirm it will open as desired when installed a PRESENT a credential known to the EAC b LIFT lever and T...

Страница 13: ...3085006 002 Rev 3 13 This page intentionally left blank...

Страница 14: ...D JQ6 ICLASSBTM Model KS210 Contains IC ID 2236B ICLASSBTM Canada Radio Certification This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two...

Отзывы: