11
Installation continued
H. Attach trim ground wire.
1. Connect pin 5 green/yellow ground wire ring
terminal (from inside trim) to top left screw.
(Figure 15)
I. Connect Electrolynx
®
harness.
(for Access 600 x M802)
NOTE: If installing an Access 600 M812
proceed to step K.
1. Connect P3 (2-pin connector) from lockbody
or MELR assembly to J3 on interior PCB
assembly.
2. Connect P4 (6-pin connector) from lockbody
assembly to J4 on interior PCB assembly.
3. Connect P5 (7-pin connector) from Reader
board to J5 on interior PCB assembly.
4. Connect ElectroLynx
®
harness (4 and 8-pin)
from door harness to ElectroLynx
®
harness
on interior PCB assembly. (Figure 16)
NOTES:
• Connectors attach properly in only one
orientation.
• Do not offset connector.
• Be sure connection is secure by gently
tugging on wire.
From Reader
Board P5 to J5
From Lock
Body or MELR
Assembly
P3 to J3
From Lock
Body P4 to J4
J1
J2
To ElectroLynx
Harness
8-pin
ElectroLynx
4-pin
ElectroLynx