Key

Outside Lever

Cylinder

Cylinder Spacer

7

Install Inside Components

1.  Remove rose from inside spring housing assembly.
2.  Align and insert inside spring housing onto the installed lockbody.
3.  Install screws to tighten the lock to the door.
4.  Orient dimples on side of rose with openings on side of spring housing assembly. See Figure 8.
5.  Install rose onto the inside spring housing assembly.
6.  In the unlocked position, verify the button is adjusted properly.  See Figure 9 for proper alignment. Adjust if necessary.
7.  Install inside lever.

Note:  Test for proper operation before closing door.

Button in-line with shank in-
dicates correct position based 
upon door thickness. If the 
button needs to be adjusted, 
position it by depressing the 
plunger, moving it in or out as 
needed.

Shank

Plunger

Screws (2) #12-24 x 1-1/2" 

Figure 8 

  

Figure 9 

  

Rose dimple

8

Cylinder Installation

IMPORTANT
Before installing cylinders: 
• 

Use a flat blade screwdriver to rotate cam until the driver points 
are in a 6 and 12 o’clock position. (See Figure 16 on next page)

Correct Key Orientation During Assembly

C

C

New Core

• 

Remove temporary construction core or plastic core.  If keyed, use 
Control Key. Rotate 15°  and pull.

• 

Insert permanent core into lever with control key. Rotate 15° and 
remove key.

Figure 10 

  

Figure 11 

  

  Standard Cylinder (Figure 10)

  Interchangeable or Removable Core (Figure 11)

Verify that the cylinder spacer is already installed into the shank on the outside
spring housing assembly. Cylinder spacer should be removed for 7-Pin cylinder.
Note orientation of spacer, if it needs to be reinstalled.

Rose dimple opening

Содержание Corbin Russwin CLX3300

Страница 1: ...ody assembly with rose liner 7 Outside spring housing assembly 8 Cylinder spacer 9 Cylinder 10 Outside lever handle 11 Key 12 Lever release tool 13 Latch 14 Screws strike 2 12 24 x 1 15 Strike 16 Stri...

Страница 2: ...oor preparation for errors Latch bolt tail should be centered in depth of retractor If it is not refer to Section 5 to properly adjust the lock for door thickness Lock is factory preset for 1 3 4 44mm...

Страница 3: ...gnment Adjust if necessary 7 Install inside lever Note Test for proper operation before closing door Button in line with shank in dicates correct position based upon door thickness If the button needs...

Страница 4: ...9 Lever Removal Installation Lever catch To Remove Remove core and tailpiece using key marked control Insert slotted screwdriver or lever release tool into cylinder opening and make contact with leve...

Страница 5: ...loy com www corbinrusswin com Remove b Install Half Dummy CLX3350 1 Remove inside lever See Section 9 2 Remove rose 3 Remove 2 mounting screws and inside housing assembly 4 Remove outside trim assembl...

Страница 6: ...43 3658 techsupport corbinrusswin assaabloy com www corbinrusswin com c Install Full Dummy CLX3370 Figure 19 11 Other Function Instructions continued Figure 20 12 Miscellaneous Options Install 1 adapt...

Страница 7: ...nscrew threaded cap from end of core it will be necessary to depress the locking pin 4 Place tailpiece inside the exposed end of core with locking pin in open slot 5 Reverse step 3 to reinstall cap 6...

Страница 8: ...on the inside trim should be in the unlocked position 2 Insert adjustment tool provided with lock into interior cap as shown below 3 Rotate cap clockwise until fully tight 4 Rotate back counter clockw...

Отзывы: