CLX3300
Installation Instructions
Cylindrical Lockset
3
FM566 05/21
Copyright © 2021, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in
part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
For installation assistance contact Corbin Russwin
1-800-543-3658 • [email protected] •www.corbinrusswin.com
Key
Outside Lever
Cylinder
Cylinder Spacer
7
Install Inside Components
1. Remove rose from inside spring housing assembly.
2. Align and insert inside spring housing onto the installed lockbody.
3. Install screws to tighten the lock to the door.
4. Orient dimples on side of rose with openings on side of spring housing assembly. See Figure 8.
5. Install rose onto the inside spring housing assembly.
6. In the unlocked position, verify the button is adjusted properly. See Figure 9 for proper alignment. Adjust if necessary.
7. Install inside lever.
Note: Test for proper operation before closing door.
Button in-line with shank in-
dicates correct position based
upon door thickness. If the
button needs to be adjusted,
position it by depressing the
plunger, moving it in or out as
needed.
Shank
Plunger
Screws (2) #12-24 x 1-1/2"
Figure 8
Figure 9
Rose dimple
8
Cylinder Installation
IMPORTANT
Before installing cylinders:
•
Use a flat blade screwdriver to rotate cam until the driver points
are in a 6 and 12 o’clock position. (See Figure 16 on next page)
Correct Key Orientation During Assembly
C
C
New Core
•
Remove temporary construction core or plastic core. If keyed, use
Control Key. Rotate 15° and pull.
•
Insert permanent core into lever with control key. Rotate 15° and
remove key.
Figure 10
Figure 11
a
Standard Cylinder (Figure 10)
b
Interchangeable or Removable Core (Figure 11)
Verify that the cylinder spacer is already installed into the shank on the outside
spring housing assembly. Cylinder spacer should be removed for 7-Pin cylinder.
Note orientation of spacer, if it needs to be reinstalled.
Rose dimple opening