background image

Warranty

ASSA ABLOY Entrance Systems warrants its products to be free from defects in material and work-
manship under intended use and service for a warranty time of 12 months, beginning at time of
delivery. This warranty extends only to the original buyer of the equipment.
ASSA ABLOY Entrance Systems warrants that the software will operate substantially in accordance
with its functional descriptions and that it has been recorded on non-defective media.
The ASSA ABLOY Entrance Systems warranty does not apply to

That the software will be error-free or operate without interruption

General wear and tear on the system

Fuse, disposable batteries and glass damage

System deviations caused by installer other than ASSA ABLOY Entrance Systems

System that has been altered or damaged by vandalism or misuse

System that has been additionally equipped with non-ASSA ABLOY Entrance Systems original
branded parts and/or spare parts

Unrequired visits due to poor client communication (door working when our technician arrives,
reset, power discontinuation)

Adjustments (closing and opening speed and also detection field radars) due to customer re-
quests (excludes operational adjustments thought to create a hazard)

Water damage

Adverse weather conditions

Any damage caused, directly or indirectly, by a circumstance beyond the control of the applicable
company within ASSA ABLOY Entrance Systems, such as industrial dispute, fire, natural disaster,
war, extensive military mobilization, insurrection, requisition, seizure, embargo, restrictions in
the use of power and defects or delays in deliveries by sub-contractors caused by any such cir-
cumstances

Please note:

Non-compliance with manufacturers care and maintenance recommendations may void the
warranty.

ASSA ABLOY Entrance Systems-authorized resellers shall extend this warranty to end-users only,
but have no authority to extend a greater or different warranty on behalf of ASSA ABLOY Entrance
Systems.

A service agreement with ASSA ABLOY Entrance Systems will help secure the availability of a
fully operational system and will give priority at call-out, thus minimizing the time that the
equipment is unusable.

Service

Regular inspections by a trained and qualified person, and the frequency of service occasions,
should at minimum be made according to national regulations or industry standard, in the
absence of a national regulation. This is especially important when the installation concerns
a fire-approved door or a door with an emergency-opening function. To extend the life of your
investment and ensure safe and reliable operation of the door, we recommend a minimum
of 2 visits per year or more, depending on usage and operating conditions. Environmental as-
pects shall also be considered.

5

Issue 2013-12-18

1009729-EI-2.0

Содержание Besam SW200i

Страница 1: ...Swing Door Operator Besam SW200i User Manual Original instructions ASSA ABLOY the global leader in door opening solutions...

Страница 2: ...ting 12 Service Maintenance 12 Other products from ASSA ABLOY Entrance Systems 13 Declaration of conformity All rights in and to this material are the sole property of ASSA ABLOY Entrance Systems AB C...

Страница 3: ...sons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction by a person responsible for their safety concerning saf...

Страница 4: ...ception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Re orient the receiving antenna R...

Страница 5: ...irectly byacircumstancebeyondthecontroloftheapplicable company within ASSA ABLOY Entrance Systems such as industrial dispute fire natural disaster war extensive military mobilization insurrection requ...

Страница 6: ...ut shaft by a combination of a bevel gear and spur gears The arm system that is connected to the output shaft opens the door in a wall mounted application There is also an adjustable spring mechanism...

Страница 7: ...pecification ASSA ABLOY Entrance Systems AB Manufacturer Lodjursgatan 10 SE 261 44 Landskrona Sweden Address Besam SW200i Type 100 240 V AC 10 15 50 60 Hz Mains power supply Max 300 W Power consumptio...

Страница 8: ...the manual activation units 11 if any and walk towards the door Check that the door has opened appropriately while you pass the entrance exit Then proceed with the automatic activation units 12 in th...

Страница 9: ...our months period The cleaning should be documented To avoid damages to the profiles the brushes weather stripping must be vacuum cleaned weekly Do not expose windows doors or profiles to alkalis Both...

Страница 10: ...ean Union Product label Mandatory A Emergency break out Mandatory if approved for escape route B ASSA ABLOY Entrance Systems door sticker Mandatory if applicable to highlight the presence of the glass...

Страница 11: ...ge 9 Finger protection 9 see page 9 Troubleshooting Remedies What s wrong The door does not open Change the setting of the program selector See page 6 The motor does not start Check that there are no...

Страница 12: ...ive Environ ment Cycles hour in operation Part number Part 100 100 10 High traffic Medium traffic Low traffic 6 6 12 24 330000271 SI BK PUSH arm service kit 6 6 12 24 330000272 SI BK PULL arm service...

Страница 13: ...C 60335 2 103 EN 60335 2 103 UL 325 EC type examination or certificate issued by a notified or competent body for full address please contact ASSA ABLOY Entrance Systems AB concerning the equipment UL...

Страница 14: ...ASSA ABLOY Entrance Systems AB Lodjursgatan 10 SE 261 44 Landskrona Sweden Tel 46 10 47 47 000 Fax 46 418 284 12 www assaabloyentrance com info aaes assaabloy com...

Отзывы: