TECHNICAL DETAILS
ENGLISH
Operating voltage:
12 - 24 V DC (± 15%)
12 - 18 V AC (-10% / +15%), RMS
Current:
12 V DC
80 mA Idle
450
mA
normal
driver
1300
mA
max.
24
V
DC
40
mA
Idle
220
mA
normal
driver
600
mA
max.
Relays:
Max. 0.8 A 30 V AC/DC resist. 20 W
Operating temperature:
-20°C - +60°C
Bolt throw:
20 mm (deadbolt), 10 mm (double action bolt)
Backset:
55, 60, 65, 80, 100 mm (EL520, EL522)
30, 35, 40, 45 mm (EL420, EL422)
Forend:
20, 24 mm (EL520, EL522)
24,
28
mm
(EL420,
EL422)
Spindle:
9 mm (8 mm with snap spindle adapter)
Connection cable:
EA218 (6 m) / EA219 (10 m) 18 x 0.14 mm2
Adjustable delay:
2 - 15 s
Door clearance:
2 - 5.5 mm (between forend and strike plate)
Settable functions:
Mechanical functions:
-
Opening
direction
of
trigger
bolt
Monitoring outputs:
Bolt deadlocked
Lock
open
Trigger
bolt
in
Handle
used
Cylinder
used
Sabotage
Strike plate:
EA321, EA322, EA323, EA324, EA325, EA326, EA327, EA328,
EA329,
EA330,
EA331,
EA332
The use of a universal building key is prohibited because it can seriosly damage the lock.
TESTED ACCORDING TO THE STANDARDS
EN 179
3 7 6 1 1 3 2 2 A
Exit
EN 1125
3 7 6 1 1 3 2 1/2 A Panic exit
EN
1634-1
Fire
EN
61000-6-1:2007
EMC
EN
61000-6-3:2007
EMC
!