7) Installation Instructions (Mortise)
18
7.6) Installation of Inside Controller Escutcheon and
Electrical Connections
Inside
of Door
Keypad Ribbon
Cable
Black
Cover
Controller
Escutcheon
C A U T I O N
DOOR MUST REMAIN OPEN
DURING INSTALLATION.
USE DOOR STOP.
Security Screw
T20 Torx Bit
GASKET APPLICATION:
Peel off the adhesive protective paper from gasket.
Feed all wires and harnesses through gasket opening
as shown and firmly press gasket to escutcheon,
aligning edge of gasket with edge of escutcehon.
Keypad harness
(ribbon cable)
Ground Terminal
J3
NOT
USED
(
(
TB1
J2
J1
E1 GROUND
TAB
52-0624B
S1
23
24
1
2
J3
NOT
USED
(
(
TB1
J2
J1
E1 GROUND
TAB
52-0624B
1.
For exterior door applications it is recommended that the gaskets provided
be applied as shown.
2.
Remove black cover from the escutcheon with High Security T20 Torx bit provided.
3.
Connect the Keypad ribbon cable to the terminal on the controller.
4.
Connect the ground wire coming from the Keypad to the insulated spade lug receptacle
coming off the Controller Harness.
5.
Complete making all the connections by matching up the connectors being certain all the
connections are secure.
6.
Feed excess wire through the inside of the door hole and into outside Keypad escutcheon
cavity, being careful not to pinch wires. Gather excess wire from the controller and position
the excess into the controller escutcheon, being careful not to pinch wires.
7.
Insert (2) #10-24 screws through top and bottom of inside escutcheon and thread into
outside escutcheon. Straighten escutcheons and tighten securely, being careful to avoid
pinching wires.
Ground
Wire
8 Pin
Molex
Doorwire
2 Pin
Methode
Solenoid
2 Pin
Molex REX