38
EN
Configurations
Rotary switch S4 – configuring the relay circuit 2
The rotary switch S4 serves the function display for relay 2.
Position
Function
0 – factory setting
Relay 1 locked
Relay 2 door closed
1
Outer door handle
2
Inner door handle
3
Locking cylinder
4
Door handle coupling
5
Unlocked
6
Locked
7
Door closed
8
Alarm / fault
9
Swing door drive
Position 1 – outer door handle
Lock with split handle follower:
the relay switches when the outer door
handle is actuated.
Lock with undivided handle follower:
the relay switches when one of the door
handles is actuated.
Position 2 – inner door handle
Lock with split handle follower:
the relay switches when the inner door
handle is actuated.
Lock with undivided handle follower:
the relay switches when one of the door
handles is actuated.
Position 3 – locking cylinder
The relay switches when the locking cylinder is actuated.
Tab. 4:
Function selection
via