Assembly instruction emergency exit device 179C
ASSAABLOY Opening Solutions Sweden AB
Kungsgatan 71
SE-632 21 Eskilstuna
Sweden
0402
SS-EN 179:2008
SC0517-15
DoP 0517
15
3
6
6
B
1
3
2
2
A
A
Nödutrymningsbeslag/
Emergency exit device
179C
Ability to release: Pass
Durability of ability to release: Pass
Fire resistance: Pass
Classification according to EN 179:2008
Box
Grade
1
Category of use
3
High frequency of use
where there is little
incentive to exercise
care, i.e. where there is
a chance of an accident
occurring and of misuse
2
Durability
6
100 000 test cycles
3
Door mass
6
Up to 200 kg
4
Suitability for use on
fire/smoke doors
B
Suitable for use on fire
and smoke door
assemblies based on a
test in accordance with
EN 1634-1
5
Safety
1
All emergency exit
devices have a critical
safety function,
therefore only the top
grade is identified for
the purpose of this
European Standard
6
Corrosion resistance
3
96 h (high resistance)
7
Security
2
Emergency exit devices
are primarily for the
operation of a door
from the inside and the
security requirements
are secondary to those
of safety
8
Projection of lever
handle
2
Projection up to 100
mm (standard
projection)
9
Type of emergency
exit device
A
Emergency exit device
with "lever handle"
operation
10
Field of door
application
A
Single door, double
door: active leaf
WARNING!
The safety features of this product are essential to
its compliance with EN 179:2008. No modification
of any kind, other than those described in these
instructions, are permitted.
Before installation:
The fixing instructions should be carefully
followed during installation.
The emergency exit device is intended for
mounting on outgoing doors, single or double
door; active door leaf only.
For further information visit our website
www.assaabloyopeningsolutions.se.
Before fitting an emergency exit device to a
fire/smoke resisting door, the fire certification
of the fire door assembly on which the exit
device has been tested to prove suitability for
use on a fire door should be examined. It is of
utmost importance that an exit device is not
used on a fire door assembly of a greater fire
resistance time than approved for.
The lock case and the strike should be fitted to
provide secure engagement. Recommended
distance between the lock case and the strike is
3 ±1 mm.
The emergency exit device should normally be
installed at a height of between 900 mm and
1 100 mm from the finished floor level. Where it
is known that the majority of the occupants of
the premises will be young children,
consideration should be given to reducing the
height of the bar.
Where an emergency exit device is designed to
be fitted to a glazed door, it is essential that the
glazing is tempered or laminated glass.
Approved
2020-12-04