Assa 1125 Panikutrymningsbeslag
ASSA 179B S4 Emergency exit device
Extension piece & Screw-nut washer
2
Lock case
1
ASSA AB 090891
Edition 5
2/7
A
A
B
1
2
3
Install the
lock case,
this example
shows lock
case 711-35
Mount the
inside [ ]
and outside [ ]
extension pieces.
If any of the two
narrow profile
devices does
not have a cylinder
a screw-nut
washer [ ] is used
instead.
1
2
3
The gap
between door
and frame shall
be less than
3 mm to ensure
proper function