background image

IMPORTANT: PLEASE READ BEFORE ATTEMPTING TO

INSTALL MAGNETIC LOCK

A. Handle the equipment with care, damaging the mating

surface of the magnet or armature plate may reduce locking
efficiency.

B. The magnet mounts rigidly to the door frame. The armature

plate mounts to the door with hardware. The kit provided
allows the armature to pivot about its center to compensate
for door wear and misalignment.

C. Template use must take place with the door

in its normally closed position.

D. Firmly tighten all screws.

A

B

C

D

E

F

G

H

8.0

1.75

2.9

.81

1.0

.4

.5

.7

MAGNET DIMENSIONS (INCHES)

A

B

C

D

E

F

G

H

203.2 44.45 73.66 20.57 25.4 10.16 12.7 19.05

MAGNET DIMENSIONS (MM)

BLIND NUT

HEADER

DOOR

HEAD

3/8" (US) OR 9.5MM 

(METRIC) HOLE

B

G

H

F

CABLE

D

E

A

C

TAMPER
 CAP

GOLD 
WASHER

SOCKET CAP SCREW

1/4-20 X 3"

(US VERSION)

6MM-1MM X 75MM

(METRIC VERSION)

Fig. 2 ARMATURE DIMENSIONS AND ASSEMBLY

Important: Armature plate must be able to float

freely. Do not over tighten. The armature
plate will automatically adjust to the
proper position with the magnet.

Fig. 1 STANDARD MAGNET DIMENSIONS

AND ASSEMBLY

A

B

C

D

E

F

F

A

B

C

D

E

F

6.0

2.75

.5

1.37

3

2.25

152.4

69.9

12.7

34.8

76.2

57.2

ARMATURE DIMENSIONS

(IN.)

(MM)

INSTALLATION INSTRUCTIONS

1584 - 1587 Series Electromagnetic Locks

FOR ASSISTANCE CONTACT SARGENT AT 800-810-WIRE (9473) or www.sargentlock.com