3
Copyright © 2009, Sargent Manufacturing Company, an ASSA ABLOY Group
company. All rights reserved. Reproduction in whole or in part without the
express written permission of Sargent Manufacturing Company is prohibited.
A7361A
STOP
(2) #14 HEX
SHEET METAL
SCREW
Z BRACKET
DOOR
MAGNALOCK
DOOR
HEADER
MOUNTING
SCREWS
WASHERS (2)
USE 1" MOUNTING
SCREW SUPPLIED
WITH Z BRACKET
A
R
M
A
T
U
R
E
SEX BOLT
(DRILL 1/2"
13 mm HOLE)
CAP SCREW
5/16"-18
(8mm-1.25mm)
DRESS COVER SLIDES ON
LAST WITH OPEN SIDE UP
AND IS ATTACHED WITH
SUPPLIED DOUBLE STICK TAPE
T-NUT REQUIRES
3/8" (10 mm) DIA HOLE
IN BRACKET AND
ACCEPTS STRIKE
MOUNTING SCREW.
ROLL PIN PLASTIC
BUSHINGS REQUIRE 1/2"
(13 mm) HOLES AND MUST
BE SHORTENED TO WORK
IN Z BRACKET.
Fig. 5 FACE MOUNT MAGNET DIMENSIONS
AND ASSEMBLY
A
B
C
D
E
F
G
G
GOLD WASHER
BLIND NUT
CABLE EXIT
TAMPER CAP
(US VERSION)
1/4-20 X 2 1/2"
(METRIC VERSION)
6mm-1mm X 60mm
DOUBLE DOOR MOUNTING
It is very common to use electromagnetic locks on double doors as most electromechanical locks cannot be utilized. In some cases
one of the door leaves is inactive so that only one leaf is used and this is secured by a single electromagnetic lock. If both leaves
are to be active, 2 electromagnetic locks can be used. For the most attractive installation, they should be butted together but if
obstructions exist in the header that interferes with mounting, the magnets can be separated and covered with an 18" dress cover
for push applications.
Fig. 4.2 TYPICAL MOUNTING FOR A PULL
APPLICATION WITH Z BRACKET
In cases where the electromagnetic lock must be
mounted on the inswinging side of the door to
protect it from physical assault, the magnet body is
mounted flush on the wall above the door frame and
a “Z” bracket is affixed to the door which positions
the armature in front of the magnet (part #15-2114
or Z bracket). SARGENT’s 1586 and 1587
electromagnetic locks have mounting holes through
the face of the magnet and wire that exits to the rear
for pull mounting applications. Figure 5 shows this
configuration. Note that when the roll pin bushings
are used, they protrude through the Z bracket and
interfere with the Z bracket cover. Roll pin bushings
must be used to provide insulation. They should be
cut with a hacksaw to function in the bracket.
A
B
C
D
E
F
G
8.0
1.75
2.9
.5
1.48
.5
.45
MAGNET DIMENSIONS (INCHES)
A
B
C
D
E
F
G
203.2
44.45 73.66 12.7 37.59 12.7 11.43
MAGNET DIMENSIONS (MM)