background image

62

63

English

Rank Interleaving

Use this item to select Rank Interleaving setting.

RAS Mode

Enable or disable RAS modes. Enabling Sparing and Mirroring is not supported. If 
enabled, Sparing will be selected.

Memory Rank Sparing

Enable or disable Memory Rank Sparing.

Memory Power Savings Mode

Use this item to configure CKE and related Memory Power Savings Features.

Numa

Use this item to enable or disable Non Uniform Memory Access (NUMA).

Содержание OCP-C612HM

Страница 1: ...OCP C612HM User Manual Version 1 0 Published September 2016 Copyright 2016 ASRock Rack INC All rights reserved...

Страница 2: ...implied including but not limited to the implied warranties or conditions of merchantability or fitness for a particular purpose In no event shall ASRock Rack its directors officers employees or agen...

Страница 3: ...ant to know more about ASRock Rack you re welcome to visit ASRock Rack s website at www ASRockRack com or you may contact your dealer for further information ASRock Rack Incorporation 6F No 37 Sec 2 J...

Страница 4: ...Pre installation Precautions 13 2 3 Installing the CPU 14 2 4 Installing the CPU Fan and Heatsink 17 2 5 Installation of Memory Modules DIMM 18 2 6 Expansion Slot PCI Express Slot 21 2 7 Jumper Setup...

Страница 5: ...4 3 3 6 USB Configuration 46 3 3 7 Chipset Configuration 47 3 3 8 Hard Disk S M A R T Settings 49 3 3 9 3rd Storage Configuration 50 3 3 10 H W Monitor 51 3 3 11 WHEA Configuration 52 3 3 12 Instant F...

Страница 6: ...Support CD Information 78 4 2 1 Running The Support CD 78 4 2 2 Drivers Menu 78 4 2 3 Utilities Menu 78 4 2 4 Contact Information 78 Chapter 5 Troubleshooting 79 5 1 Troubleshooting Procedures 79 5 2...

Страница 7: ...Rock Rack OCP C612HM Motherboard Half Form Factor 6 5 in x 20 in 16 5 cm x 50 8 cm Support CD User Manual If any items are missing or appear damaged contact your authorized dealer Because the motherbo...

Страница 8: ...s Up to maximum 1024 GB with 64GB DIMMs Voltage 1 2V DIMM Sizes RDIMM 32GB 16GB 8GB 4GB LRDIMM 64GB 32GB Expansion Slot PCIe 3 0 x 24 1 slot supports ASRock Rack OCP RB only Storage SATA Controller In...

Страница 9: ...eader 1 Type A USB2 0 1 Mezzanine Yes System BIOS BIOS Type 128Mb AMI UEFI Legal BIOS with GUI support BIOS Features Plug and Play PnP ACPI 2 0 Compliance Wake Up Events SMBIOS 2 8 Support ASRock Rack...

Страница 10: ...st Environment Temperature Operation temperature 10 C 35 C Non operation temperature 40 C 70 C This motherboard supports Wake from on Board LAN To use this function please make sure that the Wake on M...

Страница 11: ...utility you can press the F6 key during the POST or the F2 key to enter into the BIOS setup menu to access ASRock Rack Instant Flash Just launch this tool and save the new BIOS file to your USB flash...

Страница 12: ...1 11 12 13 NUT1 NUT2 NUT3 NUT4 M2_1 1 TPM1 1 AUX_PANEL1 USB3_5 SATA_4 SATA_5 CPU_1 LAN2 MEZZ_1 1 1 1 1 1 1 PECI_SEL1 SATA_PWR2 ME_RECOVERY1 J100 DEBUG_1 SSATA_0_3 SATA_0_3 PCIE_PWR1 1 VGA1 1 IPMI_LAN_...

Страница 13: ...r PCIE_PWR1 17 LGA 2011 CPU Socket R3 Narrow ILM CPU_1 18 2 x 288 pin DDR4 DIMM Slots DDR4_C1 DDR4_D1 Blue 19 2 x 288 pin DDR4 DIMM Slots DDR4_C2 DDR4_D2 White 20 LGA 2011 CPU Socket R3 Narrow ILM CPU...

Страница 14: ...5 ME Recovery Jumper ME_RECOVERY1 46 TPM Header TPM1 47 NCSI Mode Jumper NCSI_SEL1 48 BMC SMBus Header BMC_SMB_1 49 Power Switch PWR_PWR_1 50 Reset Switch RESET_BTN_1 The M 2 slot M2_1 is shared with...

Страница 15: ...BIOS B TPM2 1 1 SPEAKER1 1 SATA_PWR1 DDR4_A1 64 bit 288 pin module Blue DDR4_A2 64 bit 288 pin module White DDR4_B1 64 bit 288 pin module Blue DDR4_B2 64 bit 288 pin module White DDR4_D2 64 bit 288 p...

Страница 16: ...Power LED Chassis Identifi cation LED Solid Blue Power on Chassis identify off Off Power off Chassis identify off Blinking Blue LED on for 0 1sec off for 0 9sec and loop Power off Chassis identify on...

Страница 17: ...ications There are two LED next to the LAN port Please refer to the table below for the LAN port LED indications LAN Port LED Indications Speed LED Activity Link LED Status Description Status Descript...

Страница 18: ...es processors DDR4 ChannelE DDR4 ChannelF DDR4 ChannelG DDR4 ChannelH DDR4 1600 1866 2133 DDR4 1600 1866 2133 DDR4 1600 1866 2133 DDR4 1600 1866 2133 QPI PORT0 QPI PORT1 PCH Intel C612 DMI X2 PCIE X16...

Страница 19: ...settings 1 Unplug the power cord from the wall socket before touching any components 2 To avoid damaging the motherboard s components due to static electricity NEVER place your motherboard directly on...

Страница 20: ...or if there are any bent pins in the socket Do not force to insert the CPU into the socket if above situation is found Otherwise the CPU will be seriously damaged 2 Unplug all power cables before inst...

Страница 21: ...OCP C612HM 15 English A 3 B 4 5...

Страница 22: ...16 English The cover must be placed if returning the motherboard for after service 6 A B 7 8 B A...

Страница 23: ...Fan and Heatsink C P U _ F A N 1 2 CPU fan for narrow ILM socket Support an active or passive heatsink Before you installed the heatsink you need to spray thermal interface material between the CPU a...

Страница 24: ...DDR4 slot otherwise this motherboard and DIMM may be damaged 2 For dual channel configuration you always need to install identical the same brand speed size and chip type DDR4 DIMM pairs 3 It is unabl...

Страница 25: ...OCP C612HM 19 English The DIMM only fits in one correct orientation It will cause permanent damage to the motherboard and the DIMM if you force the DIMM into the slot at incorrect orientation 1 2 3...

Страница 26: ...the motherboard make sure to install DIMMs into DDR4_A DDR4_B DDR4_C or DDR4_D slot s 1 CPU Configuration CPU1 A1 A2 B1 B2 C1 C2 D1 D2 1 DIMM 2 DIMMS 4 DIMMS 8 DIMMS 2 CPU Configuration CPU1 A1 A2 B1...

Страница 27: ...rd please make sure that the power supply is switched off or the power cord is unplugged Please read the documentation of the expansion card and make necessary hardware settings for the card before yo...

Страница 28: ...l Mode Default ME Recovery Mode NCSI Mode Jumper 3 pin NCSI_SEL1 see p 6 No 47 NCSI is set to onboard LAN1 Default NCSI is set to Mezzanine Card Descriptor Security Over ride Jumper 3 pin J100 see p 6...

Страница 29: ...system Chassis ID0 Jumper 3 pin CHASSIS_ID0 see p 6 No 40 Chassis ID1 Jumper 3 pin CHASSIS_ID1 see p 6 No 39 Chassis ID2 Jumper 3 pin CHASSIS_ID2 see p 6 No 38 Reserved for system level use For OCP3 1...

Страница 30: ...restart PLED System Power LED Connect to the power status indicator on the chassis front panel The LED is on when the system is operating The LED is off when the system is in S4 sleep state or powered...

Страница 31: ...AN2_LED These two 2 pin headers allow you to use the Gigabit internet indicator cable to connect to the LAN status indicator When this indicator flickers it means that the internet is prop erly connec...

Страница 32: ...AKER 1 5V DUMMY DUMMY Please connect the chassis speaker to this header System Fan Connectors 6 pin CPU_FAN1 see p 6 No 25 6 pin CPU_FAN1 see p 6 No 26 GND 1 12V TACH PWM This motherboard provides two...

Страница 33: ...m temperature Non Maskable Interrupt Button Header NMI_BTN1 see p 6 No 37 CONTROL GND 1 Please connect a NMI device to this header Intelligent Platform Management Bus header 4 pin IPMB1 see p 6 No 2 I...

Страница 34: ...nector 8 pin PCIE_PWR1 see p 6 No 16 4 8 1 5 12V GND Connect one end of the power cable to this PCIE power connector and the other end to the power connector on the riser card SATA Power Connector 8 p...

Страница 35: ...OM_TX SYSTEM_RESET_N UR_CH_SEL DEBUGHEADER_COM_RX LOWHEX_1 LOWHEX_3 HIGHHEX_3 HIGHHEX_1 The connector is used for debug purpose Sideband Connector 8 pin SIDEBAND1 see p 6 No 23 1 PS_REDUDENT_LOST_N 3V...

Страница 36: ...system Reset Switch RESET_BTN1 see p 6 No 50 Reset Switch allows users to quickly reset the system 2 10 Driver Installation Guide To install the drivers to your system please insert the support CD to...

Страница 37: ...ter handles all non TCP IP traffic The Secondary adapter will receive fallback traffic if the primary fails If the Preferred Primary adapter fails but is later restored to an active status control is...

Страница 38: ...GFF Socket 3 supports SSD drives Please note that the WiFi or other non SSD M 2 modules are not supported The M 2 slot M2_1 is shared with the SATA_4 connector When M2_1 is populated with a M 2 SATA3...

Страница 39: ...he nut to be used Hand tighten the standoff into the desired nut location on the motherboard B C A Step 5 Align and gently insert the M 2 NGFF SSD module into the M 2 slot Please be aware that the M 2...

Страница 40: ...bar with the following selections Item Description Main To set up the system time date information Advanced To set up the advanced UEFI features IntelRCSetup For Intel CPU and chipset settings Server...

Страница 41: ...r the selected items Tab Switch to next function Enter To bring up the selected screen PGUP Go to the previous page PGDN Go to the next page HOME Go to the top of the screen END Go to the bottom of th...

Страница 42: ...2 Main Screen Once you enter the UEFI SETUP UTILITY the Main screen will appear and display the system overview The Main screen provides system overview information and allows you to set the system t...

Страница 43: ...SM Parameters Trusted Computing USB Configuration Chipset Configuration Hard Disk S M A R T Settings 3rd Storage Configuration H W Monitor WHEA Configuration and Instant Flash Save User Default Type a...

Страница 44: ...guration PCIE Devices Power On Use this item to enable or disable PCIE devices to turn on the system from the power soft off mode RTC Alarm Power On Use this item to enable or disable RTC Real Time Cl...

Страница 45: ...he followings Serial Port Use this item to enable or disable Serial Port COM Serial Port Address Use this item to select an optimal setting for Super IO device SOL Configuration Use this item to set p...

Страница 46: ...igure Console Redirection Settings and specify how your computer and the host computer to which you are connected exchange information Terminal Type Use this item to select the preferred terminal emul...

Страница 47: ...can be sent to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow uses two wires to send start stop signals The options include None and Hardwar...

Страница 48: ...elect the preferred terminal emulation type for out of band management It is recommended to select VT UTF8 Option Description VT100 ASCII character set VT100 Extended VT100 that supports color and fun...

Страница 49: ...e that support legacy option ROM only Select Do not launch to not execute both legacy and UEFI option ROM PCIE1 x8 Slot OpROM Use this option to select PCIE1 x8 Storage and Network Option ROM policy P...

Страница 50: ...nding Operation Schedule an Operation for the Security Device NOTE Your computer will reboot during restart in order to change State of the Device Platform Hierarchy Use this item to enable or disable...

Страница 51: ...ect TPM 1 2 will restrict support to TPM 1 2 devices TPM 2 0 will restrict support to TPM 2 0 devices Auto will support both with the default set to TPM 2 0 devices If TPM 2 0 devices are not found TP...

Страница 52: ...ptions Enabled Disabled Auto and Smart Auto If Auto is selected all USB ports work as USB3 0 after boot to OS If Smart Auto is selected all USB ports work as USB3 0 after boot to OS and work as USB2 0...

Страница 53: ...e is Auto Onboard LAN1 This allows you to enable or disable both the Onboard LAN1 features Onboard LAN2 This allows you to enable or disable both the Onboard LAN2 features Above 4G Decoding Enable or...

Страница 54: ...ower Loss This allows you to set the power state after an unexpected AC power loss If Power Off is selected the AC power remains off when the power recovers If Power On is selected the AC power resume...

Страница 55: ...English 3 3 8 Hard Disk S M A R T Settings Hard Disk S M A R T Use this item to enable or disable the S M A R T Self Monitoring Analysis and Reporting Technology feature Configuration options Disable...

Страница 56: ...50 English 3 3 9 3rd Storage Configuration In this section you may set the configurations for the supported 3rd storage device...

Страница 57: ...tor the status of the hardware on your system includ ing the parameters of the CPU temperature motherboard temperature CPU fan speed chassis fan speed and the critical voltage Watch Dog Timer This all...

Страница 58: ...log features S W Error Injection Support When it is set to Enabled S W Error Injection is supported by unlocking MSR Ox790 Memory Error Use this item to enable or disable Memory Error log feature Cor...

Страница 59: ...le PCIE Error log feature Corrected Error Enable Use this item to enable or disable PCIe Correctable errors Uncorrected Error Enable Use this item to enable or disable PCIe Uncorrectable errors Fatal...

Страница 60: ...isk or hard drive and launch this tool then you can update your UEFI only in a few clicks without preparing an additional floppy diskette or other compli cated flash utility Please be noted that the U...

Страница 61: ...p In this section you may set the configurations for the following items Processor Configu ration CPU Power Management Configuration QPI Configuration Memory Configura tion IIO Configuration PCH Confi...

Страница 62: ...cores to be enabled 0 means all cores Intel Hyper Threading Technology Intel Hyper Threading Technology allows multiple threads to run on each core so that the overall performance on threaded softwar...

Страница 63: ...dependent partitions so that one computer system can function as multiple virtual systems Enable SMX Use this item to enable Safer Mode Extensions PPIN Control Use this item to unlock and Enable Disab...

Страница 64: ...f the current CPU does not support Intel R SpeedStep technology Intel Turbo Boost Technology Use this item to enable or disable Intel Turbo Boost Technology Turbo Boost allows processor cores to run f...

Страница 65: ...value in seconds The value may vary from 0 to 56 Pkg Clmp Lim1 Pkg Clamping limit 1 allowing going below P1 O PBBM limited between P1 and P0 1 PBM can go below P1 Short Dur Pwr Limit En Use this item...

Страница 66: ...lect the QPI link speed as either the POR speed Fast or default speed Slow Link Frequency Select Allows for selecting the QPI Link Frequency COD Enable Use this item to enable or disable Cluster on Di...

Страница 67: ...will detect the memory module s inserted and assign the appropriate frequency automatically ECC Support Use this item to enable or disable DDR ECC Support Enable ADR Use this item to enable the ADR M...

Страница 68: ...s Enabling Sparing and Mirroring is not supported If enabled Sparing will be selected Memory Rank Sparing Enable or disable Memory Rank Sparing Memory Power Savings Mode Use this item to configure CKE...

Страница 69: ...d The default value is Auto PCIE1 x8 Slot Link Speed This allows you to select PCIE1 x8 port Link Speed The default value is Auto MEZZ_1 Slot Link Speed This allows you to select MEZZ_1 Slot Link Spee...

Страница 70: ...nd settings sSATA Controller Use this item to enable or disable SATA Controller sSATA Mode Selection Identify the SATA port is connected to Solid State Drive or Hard Disk Drive Press Ctrl I to enter R...

Страница 71: ...SATA port connected to Solid State Drive or Hard Disk Drive PCH SATA Configuration SATA devices and settings SATA Controller Use this item to enable or disable SATA Controller SATA M 2_SATA Mode Sele...

Страница 72: ...Up will be performed and only the drives which have this option enabled will spin up at boot Otherwise all drives spin up at boot SATA Rx Setting Adjust SATA DTLE DATA Values 0 15 SATA Device Type Ide...

Страница 73: ...OCP C612HM 67 English 3 4 7 Server ME Configuration Altitude Use this item to select the system altitude above the sea level in meters Spread Spectrum Use this item to select spread specturm mode...

Страница 74: ...5 Server Mgmt Wait For BMC Wait For BMC response for specified time out In PILOTII BMC starts at the same time when BIOS starts during AC power ON It takes around 30 seconds to initialize Host to BMC...

Страница 75: ...features of System Event Logging during boot Erase SEL Use this to choose options for earsing SEL When SEL is Full Use this to choose options for reactions to a full SEL Log EFI Status Codes Use this...

Страница 76: ...ddress toggle to Yes and the changes take effect after the system reboots The default value is No Configuration Address Source Select to configure BMC network parameters statically or dynamically by B...

Страница 77: ...word admin For more instructions on how to set up remote control environment and use the IPMI man agement platform please refer to the IPMI Configuration User Guide or go to the Support website at htt...

Страница 78: ...or change the password for the administrator account Only the administrator has authority to change the settings in the UEFI Setup Utility Leave it blank and press enter to remove the password User Pa...

Страница 79: ...This shows the number of seconds to wait for setup activation key 65535 0XFFFF means indefinite waiting Bootup Num Lock If this item is set to On it will automatically activate the Numeric Lock functi...

Страница 80: ...Option Policy Use this item to control the placement of newly detected UEFI boot options Boot Mode Select Use this item to select boot mode LEGACY UEFI When you select UEFI mode you will see the foll...

Страница 81: ...Every reset If Yes is selected all logged events will be erased When Log is Full Use this item to choose options for reactions to a full Smbios Event Log The options include Do Nothing and Erase Imme...

Страница 82: ...76 English View Smbios Event Log Press Enter to view the Smbios Event Log records All values changed here do not take effect until computer is restarted...

Страница 83: ...ng message Discard changes and exit setup will pop out Press ESC key or select Yes to exit the UEFI SETUP UTILITY without saving any changes Discard Changes When you select this option the following m...

Страница 84: ...res 4 2 1 Running The Support CD To begin using the support CD insert the CD into your CD ROM drive The CD automatically displays the Main Menu if AUTORUN is enabled in your computer If the Main Menu...

Страница 85: ...o default settings 3 Check the settings of the 115V 230V switch on the power supply 4 Verify if the battery on the motherboard provides 3VDC Install a new battery if it does not If there is no video 1...

Страница 86: ...battery on the motherboard provides 3VDC Install a new battery if it does not 2 Confirm whether your power supply provides adaquate and stable power Other problems 1 Try searching keywords related to...

Страница 87: ...a copy of your invoice marked with the date of purchase is required By calling your vendor or going to our RMA website http event asrockrack com tsd asp you may obtain a Returned Merchandise Authoriza...

Страница 88: ...equired to install Net Framework Please follow the steps below to enable Net Framework feature on Microsoft Windows Server 2008 R2 6 1 Installing Net Framework 3 5 1 For Server 2008 R2 1 Double click...

Страница 89: ...OCP C612HM 83 English 3 Check the box next to Net Framework 3 5 1 and then click Next 4 Click Next to continue...

Страница 90: ...84 English 5 Click Install to start installing Net Framework 3 5 1 6 After the installation completes click Close...

Страница 91: ...pe Mezz Slot Type Model LAN Card Mezz Type A M350 LAN Card Mezz Type A M350R LAN Card Mezz Type A M540 LAN Card Mezz Type A M599 LAN Card Mezz Type A M599R LAN Card Mezz Type A M710 Storage Card Mezz...