Supplier
Air conditioning
Outdoor unit
AAS3012B
AAS3018B
Indoor unit
Outdoor unit
dB
63
65
Sound power
Indoor unit
dB
57
59
Type
R32
R32
GWP
kgCO
2eq
675
675
Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential
(
GWP
)
would contribute less to global warming than a refrigerant with higher GWP, if leaked to
the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 675. This means
that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global
warming would be 675 times higher than 1 kg of CO2, over a period of 100 years. Never try to
interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a
professional.
Refrigerant
Cooling mode
SEER
5.6
6.3
Energy class
A+
A++
cooling
Qce
kWh/year
200
256
performance Energy consumption is based on standard test results. Actual energy consumption will depend on
how the appliance is used and where it is located.
Pdesignc
kW
3.2
4.6
Heating mode: Average climate
Pdesignh
temperature
℃
-10
-10
SCOP
3.8
4.0
Energy class
A
A+
Heating
Qhe
kWh/year
958
1155
performance Energy consumption is based on standard test results. Actual energy consumption will depend on
how the appliance is used and where it is located.
Pdesignh
kW
2.6
3.3
Back-up heating capacity
kW
0.5
0.4
Heating mode: Warm climate
Pdesignh temperature
℃
2
2
SCOP
4.6
4.6
Energy class
A++
A++
Heating
Qhe
kWh/year
730
913
performance Energy consumption is based on standard test results. Actual energy consumption will depend on
how the appliance is used and where it is located.
Pdesignh
kW
2.4
3.0
Back-up heating capacity
kW
0
0
Heating mode: Cold climate
Pdesignh temperature
℃
-
-
SCOP
-
-
Energy class
-
-
Heating
Qhe
kWh/year
-
-
performance Energy consumption is based on standard test results. Actual energy consumption will depend on
how the appliance is used and where it is located.
Pdesignh
kW
-
-
Back-up heating capacity
kW
-
-
Содержание AAS3012B
Страница 2: ......
Страница 17: ...WARNING CAUTION N Open the window and well ventilated the room explosion proof fuse 14 ...
Страница 19: ...R32 2 3 R 2 3 R R32 R32 R32 R32 R32 16 ...
Страница 21: ...R32 R32 R32 R32 R32 R32 R32 R32 R32 18 ...
Страница 22: ...3 R32 R32 R32 R32 R32 R32 R32 19 ...
Страница 23: ...R32 R32 R32 R32 R32 R32 R32 R32 10A HFC 410A 20 ...
Страница 26: ...23 ...
Страница 27: ...24 R32 R32 ...
Страница 58: ......
Страница 59: ...0011523469 ...
Страница 60: ...www aspes es ...