ASP Intelligent RS-422 Скачать руководство пользователя страница 10

Intelligent RS-485 and RS-422 Adaptors

 

Technical Information 

This section of the manual details the pinouts of the Intelligent RS-485 
and RS-422 Adaptors. 

RS-232 Connector 

The female DB-25 connector on the Intelligent RS-485 and RS-422 
Adaptors is designed to plug straight into a DB-25 or DB-9 serial port 
on your PC, using a standard PC serial cable.  Listed below are the 
connector pinouts, along with the equivalent pins on both DB-25 and 
DB-9 PC serial port connectors, in case you want to make your own 
cable. 

Pin Function 

DB-25 on PC

DB-9 on PC 

Data from PC 

Data to PC 

7 Signal 

Ground

 

Note that the Intelligent RS-485 and RS-422 Adaptors use only the 
transmit and receive data lines and signal ground.  However, since 
some PC’s may require the RS-232 handshaking lines to be correctly 
set, the Intelligent RS-485 and RS-422 Adaptors connects the RTS and 
CTS lines together (pins 4 and 5), and the DSR, CD and DTR lines 
together (pins 6, 8 and 20). 

RS-485 Connector 

The RS-485 port on the Intelligent Adaptor is a standard DB9 Female 
connector, wired as follows: 

Pin Function 

1 & 2  Power Supply -ve 

3 Protective 

Ground 

4 & 5  Power ve 

6 & 7  RS-485 B (+ve) 

8 & 9  RS-485 A (-ve) 

 

Содержание Intelligent RS-422

Страница 1: ...rocomputers 14 Business Park Drive Notting Hill Victoria 3168 Australia Telephone 03 9578 7600 FAX 03 9578 7727 email solutions asp com au World Wide Web http www asp com au ASP Microcomputers is a di...

Страница 2: ......

Страница 3: ...S 485 and RS 422 Cabling 2 Cable Termination 3 Power Supplies 4 Network Expansion 5 The Main Cabling Points Again 5 Technical Information 6 RS 232 Connector 6 RS 485 Connector 6 RS 422 Connector 7 RJ...

Страница 4: ......

Страница 5: ...ocol to communicate with to the PC with the PC being the master Because RS 422 uses a separate pair of wires for data in each direction the Intelligent RS 422 adaptor is always able to both send and r...

Страница 6: ...minal Networked Portable BCR WandNet ASP RS 422 and RS 485 networks must be wired using a single run of shielded twisted pair cable daisy chained to each unit The cable must be looped to each unit in...

Страница 7: ...ch contain two or three twisted pairs of wires respectively are available in 100 metre and 500 metre rolls from A G Garlands Co Pty Ltd in Melbourne phone 03 9543 6411 with offices in other states Oth...

Страница 8: ...S cable for RS 485 installations and MCP 3S cable for RS 422 installations provides for a spare pair of wires In some installations it will be possible to use this spare pair to provide power over the...

Страница 9: ...erial ports Remember that each section of the network can be up to 1200 metres long and can support up to 31 units Although we have had some users connect more than 31 units together in a single netwo...

Страница 10: ...nt to make your own cable Pin Function DB 25 on PC DB 9 on PC 2 Data from PC 2 3 3 Data to PC 3 2 7 Signal Ground 7 5 Note that the Intelligent RS 485 and RS 422 Adaptors use only the transmit and rec...

Страница 11: ...Supply ve RJ 45 Connector The Intelligent RS 485 and RS 422 Adaptors also provide for the use of Category 3 or Category 5 twisted pair cable via an RJ 45 socket on the front panel This connector is wi...

Страница 12: ...RS 485 adaptor the RS 422 adaptor uses the same physical PCB but with different components fitted Jumper 1 if fitted connects unregulated DC voltage from the plug pack powering the Adaptor to the RS 4...

Страница 13: ...will be paid by ASP in the case of warranty repairs ASP welcomes suggestions for improvements to our products and documentation Year 2000 Statement The Intelligent RS 485 and RS 422 Adaptors are hard...

Отзывы: