ASO Safety Solutions SENTIR edge 25.45 CT Скачать руководство пользователя страница 17

Notes

17

Содержание SENTIR edge 25.45 CT

Страница 1: ...Product Information US Edition 25 45 ASO Inc All Rights Reserved C 25 45 ...

Страница 2: ...5 CT SENTIR edge 25 45 TTLa SENTIR edge 25 45 TTLL edge 25 45 Ts T La SENTIR ASO Safety contact edges Profile width Profile height Sealing lip La Single sided outwards LL Double sided outwards Material Base shape T T base Ts T base small CT Clips base 2 ...

Страница 3: ...H Zertifizierungen Certificates EN ISO 13856 2 EN 12978 EN ISO 13849 1 UL 325 SENTIR edge 25 45 CT SENTIR edge 25 45 T s TLa SENTIR edge 25 45 FTLa 3 71 5 50 8 25 Specifications All shown variants are also availiable with smaller base shape Ts Dimension in mm Tolerances according to DIN ISO 3302 1 class E2 3 ...

Страница 4: ... distance c 7 7 mm Overtravel distance d to 250 N 19 9 mm Overtravel distance f to 400 N 22 7 mm Overtravel distance h c to 600 N 24 8 mm Test Speed 100 mm s Actuation Force FA 60 4 N Actuation distance c 10 0 mm Overtravel distance d to 250 N 19 8 mm Overtravel distance f to 400 N 22 6 mm Overtravel distance h c to 600 N 24 5 mm Test Speed 200 mm s Characteristics for test temperature 20 C The re...

Страница 5: ... mm Overtravel distance d to 250 N 19 9 mm Overtravel distance f to 400 N 22 7 mm Overtravel distance h c to 600 N 24 8 mm Test Speed 100 mm s Actuation Force FA 60 4 N Actuation distance c 10 0 mm Overtravel distance d to 250 N 19 8 mm Overtravel distance f to 400 N 22 6 mm Overtravel distance h c to 600 N 24 5 mm Test Speed 200 mm s Characteristics for test temperature 20 C The response time of ...

Страница 6: ...tuation distance c 10 8 mm Overtravel distance d to 250 N 22 8 mm Overtravel distance f to 400 N 26 2 mm Overtravel distance h c to 600 N 28 7 mm Test Speed 100 mm s Actuation Force FA 60 6 N Actuation distance c 11 3 mm Overtravel distance d to 250 N 22 3 mm Overtravel distance f to 400 N 26 0 mm Overtravel distance h c to 600 N 28 6 mm Test Speed 200 mm s Characteristics for test temperature 20 ...

Страница 7: ...EN ISO 13856 2 Test Unit round 80mm Actuating Point C3 Temp 20 C 50 150 250 350 450 550 0 5 10 15 20 25 30 35 40 45 A B1 B2 c d e f g h s mm F N C Tested according DIN EN ISO 13856 2 Test Unit round 80mm Actuating Point C3 Temp 20 C 50 150 250 350 450 550 0 5 10 15 20 25 30 35 40 45 A B1 B2 c d e f g h s mm F N C Tested according DIN EN ISO 13856 2 Test Unit round 80mm Actuating Point C3 Temp 20 C...

Страница 8: ...emical resistance Water dist 1 Dilutes acid 1 Dilutes base 1 Not oxidizing acids 2 Oxidizing acids 2 ASTM oil No 3 6 Mineral oil 2 Brake fluid 2 3 Antifreezing admixture 1 Gasoline 5 Diesel 2 3 Alcohol 1 1 no effects Permanent contact 2 few effects Some contact 3 medium effects Some contact 4 noticeable effects Reduced contact 5 severve effects Very brief contact 6 extreme effects Avoid contact 1 v...

Страница 9: ...lip Contact plug KS 4 with sealing Aluminium fixation profile Double chamber profile with integrated switching chamber Lock cap End cap KS 4 W or L XX Xm 25 45 Set 1x KS 4 plug with lock cap resistor 8 2 kOhm or XX X m cable 1x End cap 25 45 2x Fixation clip 9 ...

Страница 10: ...the plug fits closely to the lock cap 5 Put on end caps Put on end cap onto the edge and fasten it while pushing fixation clip into the given space until it clicks into place For bigger contact edges an additional fixation clip is used to fasten the end cap within the profile 6 Electrical testing of the safety contact edge Measure the contact edge with a multimeter In rest position the resistance valu...

Страница 11: ...n the complete c base Pulling or pushing the safety contact edge into the aluminum profile can cause damage to the contact edge and should be avoided at all costs 7 Safety contact edges with collateral c bases at first have to be clipsed with one side into the aluminum profile Then press in the other c base Pulling or pushing the safety contact edge into the aluminum profile can cause damage to the co...

Страница 12: ...dge must be replaced immediately During the maintenance operations disconnect the machine s prime mover before working in the SENTIR edge system Observe all applicable electrical safety precautions Cleaning The profiles should be kept clean of deposits such as swarf fine metallic fillings or shavings removed by cut ting grinding or any other mechanical process debris and other foreign materials to pr...

Страница 13: ... Always adhere to the local and national electrical code specifications when wiring SENTIR edge and other controls Wire the SENTIR edge into controls as specified by the control manufacturer The safety regulations issued by the Trade Association and those for electrical installation must be considered Failure to comply with the safety regulations may result in severe or fatal injury or serious damag...

Страница 14: ...ion contained in this operating instructions manual is provided without liability and is subject to technical modi fications There are no residual risks provided that the safety instructions as well as the instructions regarding mounting commissioning operation and maintenance are observed Exclusion of Liability The manufacturer shall accept no liability for damages and malfunctions resulting from ...

Страница 15: ...Declaration of conformity 15 ...

Страница 16: ...PRODUCT INFORMATION Notes 16 ...

Страница 17: ...Notes 17 ...

Страница 18: ...3 299 www asosafety de aso eu asosafety com Headquarter USA ASO Safety Solutions Inc 300 Roundhill Drive Unit 6 Rockaway NJ 07866 Phone 1 973 7844994 Fax 1 973 5861590 www asosafety com sales us asosafety com 15 DB 13 014 Technical data rev 04 as of December 10th 2019 Technical changes reserved ...

Отзывы: