ASO Safety Solutions SENTIR edge 25.45 CT Скачать руководство пользователя страница 10

PRODUCT INFORMATION

1. Cutting the safety-contact-edge  

The safety-contact-edge is cut 24 mm shorter than the fi nal length di-

mension to allow for the length of the end caps on each end. Make sure 
that the edge is cut clean and straight.

2. Preparing end caps
a) Water drain plugs

For installations in contact with water, it is necessary to remove water 

drain plugs. If the edge is to be mounted horizontally, remove drain 

plugs from both ends. If the edge is mounted vertically, just remove the 
lower drain plug.

b) Notch for the sealing lip

When assembling safety-contact-edges with weather-sealing lips, the 
end caps have to be notched where indicated to allow for the we-
ather-sealing lip(s). 

c) Connection cable

Choose desired cable exit of end cap. If necessary, stitch through the 
marks.

3. Insert lock cap

Push in the lock cap including the held plug into the hollow spaces 
surrounding the switching chamber and  push it tight to the cut surface 
of the safety contact edge.

4. Insert the contact plug  

Insert the plug, which is hold by the lock cap, into the electrical swit-
ching chamber of the safety-contact-edge. Make sure that the plug is 

pressed in tightly until the upper  notch of the plug fi ts closely to the 

lock cap.

5. Put on end caps

Put on end cap onto the edge and fasten it while pushing fi xation clip 

into the given space until it clicks into place. For bigger contact edges 

an additional fi xation clip is used to fasten the end cap within the 
profi le.

6. Electrical testing of the safety contact edge

Measure the contact edge with a multimeter. In rest position, the 

resistance value has to be 8,2 kΩ ± 500 Ω. When edge is activated, the 
resistance should not exceed 500 Ω.

7. Cutting mounting rail

The aluminum mounting rail has to be as long as the fi nal dimension of 

the contact edge.

Assembly instructions

Safety contact edges may only be assembled and installed by authorized personnel!

Read all instructions fi rst before installing / setting up the Product!

Do not drink any alcohol or take any drugs before or during the setup of 

the Product and follow the safety instructions carefully.

!

L

= L - 2

4 mm

8,2 kΩ ± 500 Ω

ASO GmbH excludes all liability for damage caused of an incorrect assembly and installation of the contact edges!

Note Warnings and disclaimers, page 12 pt. 2

To avoid the risk of crushing while assembling or mounting, 
Safety gloves must be worn!

Due to packaging it might happen that the lip of the profi le is undulated. This appereance will not affect the functionality at 

all. This kind of appereance will in any case not be a reason for complaints.

10

11

Содержание SENTIR edge 25.45 CT

Страница 1: ...Product Information US Edition 25 45 ASO Inc All Rights Reserved C 25 45 ...

Страница 2: ...5 CT SENTIR edge 25 45 TTLa SENTIR edge 25 45 TTLL edge 25 45 Ts T La SENTIR ASO Safety contact edges Profile width Profile height Sealing lip La Single sided outwards LL Double sided outwards Material Base shape T T base Ts T base small CT Clips base 2 ...

Страница 3: ...H Zertifizierungen Certificates EN ISO 13856 2 EN 12978 EN ISO 13849 1 UL 325 SENTIR edge 25 45 CT SENTIR edge 25 45 T s TLa SENTIR edge 25 45 FTLa 3 71 5 50 8 25 Specifications All shown variants are also availiable with smaller base shape Ts Dimension in mm Tolerances according to DIN ISO 3302 1 class E2 3 ...

Страница 4: ... distance c 7 7 mm Overtravel distance d to 250 N 19 9 mm Overtravel distance f to 400 N 22 7 mm Overtravel distance h c to 600 N 24 8 mm Test Speed 100 mm s Actuation Force FA 60 4 N Actuation distance c 10 0 mm Overtravel distance d to 250 N 19 8 mm Overtravel distance f to 400 N 22 6 mm Overtravel distance h c to 600 N 24 5 mm Test Speed 200 mm s Characteristics for test temperature 20 C The re...

Страница 5: ... mm Overtravel distance d to 250 N 19 9 mm Overtravel distance f to 400 N 22 7 mm Overtravel distance h c to 600 N 24 8 mm Test Speed 100 mm s Actuation Force FA 60 4 N Actuation distance c 10 0 mm Overtravel distance d to 250 N 19 8 mm Overtravel distance f to 400 N 22 6 mm Overtravel distance h c to 600 N 24 5 mm Test Speed 200 mm s Characteristics for test temperature 20 C The response time of ...

Страница 6: ...tuation distance c 10 8 mm Overtravel distance d to 250 N 22 8 mm Overtravel distance f to 400 N 26 2 mm Overtravel distance h c to 600 N 28 7 mm Test Speed 100 mm s Actuation Force FA 60 6 N Actuation distance c 11 3 mm Overtravel distance d to 250 N 22 3 mm Overtravel distance f to 400 N 26 0 mm Overtravel distance h c to 600 N 28 6 mm Test Speed 200 mm s Characteristics for test temperature 20 ...

Страница 7: ...EN ISO 13856 2 Test Unit round 80mm Actuating Point C3 Temp 20 C 50 150 250 350 450 550 0 5 10 15 20 25 30 35 40 45 A B1 B2 c d e f g h s mm F N C Tested according DIN EN ISO 13856 2 Test Unit round 80mm Actuating Point C3 Temp 20 C 50 150 250 350 450 550 0 5 10 15 20 25 30 35 40 45 A B1 B2 c d e f g h s mm F N C Tested according DIN EN ISO 13856 2 Test Unit round 80mm Actuating Point C3 Temp 20 C...

Страница 8: ...emical resistance Water dist 1 Dilutes acid 1 Dilutes base 1 Not oxidizing acids 2 Oxidizing acids 2 ASTM oil No 3 6 Mineral oil 2 Brake fluid 2 3 Antifreezing admixture 1 Gasoline 5 Diesel 2 3 Alcohol 1 1 no effects Permanent contact 2 few effects Some contact 3 medium effects Some contact 4 noticeable effects Reduced contact 5 severve effects Very brief contact 6 extreme effects Avoid contact 1 v...

Страница 9: ...lip Contact plug KS 4 with sealing Aluminium fixation profile Double chamber profile with integrated switching chamber Lock cap End cap KS 4 W or L XX Xm 25 45 Set 1x KS 4 plug with lock cap resistor 8 2 kOhm or XX X m cable 1x End cap 25 45 2x Fixation clip 9 ...

Страница 10: ...the plug fits closely to the lock cap 5 Put on end caps Put on end cap onto the edge and fasten it while pushing fixation clip into the given space until it clicks into place For bigger contact edges an additional fixation clip is used to fasten the end cap within the profile 6 Electrical testing of the safety contact edge Measure the contact edge with a multimeter In rest position the resistance valu...

Страница 11: ...n the complete c base Pulling or pushing the safety contact edge into the aluminum profile can cause damage to the contact edge and should be avoided at all costs 7 Safety contact edges with collateral c bases at first have to be clipsed with one side into the aluminum profile Then press in the other c base Pulling or pushing the safety contact edge into the aluminum profile can cause damage to the co...

Страница 12: ...dge must be replaced immediately During the maintenance operations disconnect the machine s prime mover before working in the SENTIR edge system Observe all applicable electrical safety precautions Cleaning The profiles should be kept clean of deposits such as swarf fine metallic fillings or shavings removed by cut ting grinding or any other mechanical process debris and other foreign materials to pr...

Страница 13: ... Always adhere to the local and national electrical code specifications when wiring SENTIR edge and other controls Wire the SENTIR edge into controls as specified by the control manufacturer The safety regulations issued by the Trade Association and those for electrical installation must be considered Failure to comply with the safety regulations may result in severe or fatal injury or serious damag...

Страница 14: ...ion contained in this operating instructions manual is provided without liability and is subject to technical modi fications There are no residual risks provided that the safety instructions as well as the instructions regarding mounting commissioning operation and maintenance are observed Exclusion of Liability The manufacturer shall accept no liability for damages and malfunctions resulting from ...

Страница 15: ...Declaration of conformity 15 ...

Страница 16: ...PRODUCT INFORMATION Notes 16 ...

Страница 17: ...Notes 17 ...

Страница 18: ...3 299 www asosafety de aso eu asosafety com Headquarter USA ASO Safety Solutions Inc 300 Roundhill Drive Unit 6 Rockaway NJ 07866 Phone 1 973 7844994 Fax 1 973 5861590 www asosafety com sales us asosafety com 15 DB 13 014 Technical data rev 04 as of December 10th 2019 Technical changes reserved ...

Отзывы: