![ASO Safety Solutions SENTIR edge 25.45 CT Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/aso-safety-solutions/sentir-edge-25-45-ct/sentir-edge-25-45-ct_product-information_2984512010.webp)
PRODUCT INFORMATION
1. Cutting the safety-contact-edge
The safety-contact-edge is cut 24 mm shorter than the fi nal length di-
mension to allow for the length of the end caps on each end. Make sure
that the edge is cut clean and straight.
2. Preparing end caps
a) Water drain plugs
For installations in contact with water, it is necessary to remove water
drain plugs. If the edge is to be mounted horizontally, remove drain
plugs from both ends. If the edge is mounted vertically, just remove the
lower drain plug.
b) Notch for the sealing lip
When assembling safety-contact-edges with weather-sealing lips, the
end caps have to be notched where indicated to allow for the we-
ather-sealing lip(s).
c) Connection cable
Choose desired cable exit of end cap. If necessary, stitch through the
marks.
3. Insert lock cap
Push in the lock cap including the held plug into the hollow spaces
surrounding the switching chamber and push it tight to the cut surface
of the safety contact edge.
4. Insert the contact plug
Insert the plug, which is hold by the lock cap, into the electrical swit-
ching chamber of the safety-contact-edge. Make sure that the plug is
pressed in tightly until the upper notch of the plug fi ts closely to the
lock cap.
5. Put on end caps
Put on end cap onto the edge and fasten it while pushing fi xation clip
into the given space until it clicks into place. For bigger contact edges
an additional fi xation clip is used to fasten the end cap within the
profi le.
6. Electrical testing of the safety contact edge
Measure the contact edge with a multimeter. In rest position, the
resistance value has to be 8,2 kΩ ± 500 Ω. When edge is activated, the
resistance should not exceed 500 Ω.
7. Cutting mounting rail
The aluminum mounting rail has to be as long as the fi nal dimension of
the contact edge.
Assembly instructions
Safety contact edges may only be assembled and installed by authorized personnel!
Read all instructions fi rst before installing / setting up the Product!
Do not drink any alcohol or take any drugs before or during the setup of
the Product and follow the safety instructions carefully.
!
L
= L - 2
4 mm
8,2 kΩ ± 500 Ω
ASO GmbH excludes all liability for damage caused of an incorrect assembly and installation of the contact edges!
Note Warnings and disclaimers, page 12 pt. 2
To avoid the risk of crushing while assembling or mounting,
Safety gloves must be worn!
Due to packaging it might happen that the lip of the profi le is undulated. This appereance will not affect the functionality at
all. This kind of appereance will in any case not be a reason for complaints.
10
11
Содержание SENTIR edge 25.45 CT
Страница 1: ...Product Information US Edition 25 45 ASO Inc All Rights Reserved C 25 45 ...
Страница 15: ...Declaration of conformity 15 ...
Страница 16: ...PRODUCT INFORMATION Notes 16 ...
Страница 17: ...Notes 17 ...