SMC02G/SMC02F/Variants - Product Manual
6 Fault
Finding
Table 2
SMC02 Faults – VAR4/VAR12/VAR20
Operational Fault
Symptom
Fault
Description
Fault Code(s)
Reported and
Logged at the
VAR4/VAR12/VAR20
Suggested Action
Total loss of live audio
announcement from a
single microphone, though
the microphone still
appears to be functional.
Input audio
surveillance
IPXX AUDIO INPUT
XX=01 to 20
•
Check audio cabling or power supply
cabling between microphone and
Router.
•
Replace microphone console.
•
Replace Router.
Total loss of live audio
announcement from a
single microphone, though
the microphone still
appears to be functional.
Mic capsule fault
IPXX MIC CAPSULE
XX=01 to 20
•
Check continuity of microphone
capsule and any associated wiring, if
faulty then replace capsule if possible.
•
Replace microphone console.
•
Replace Router.
Total loss of all
functionality on a single
microphone.
Mic comms fault
IPXX MIC COMMS
XX=01 to 20
•
Check data cabling or power supply
cabling between microphone and
Router.
•
Replace microphone console.
•
Replace Router.
No operational failure on
initial fault report. Total
loss of all functionality on a
single microphone if
subsequent fault reports
within one hour.
Mic CPU reset
IPXX MIC COMMS
XX=01 to 20
•
A one-off occurrence may be
experienced due to EMI or transients.
•
Repeated occurrences indicate faulty
microphone electronics, so replace
microphone console.
Total loss of all
functionality on a single
microphone.
Mic RAM error
IPXX MIC FAULT-09
XX=01 to 20
(Mic Processor stops)
•
A one-off occurrence may be
experienced due to EMI or transients.
•
Repeated occurrences indicate faulty
microphone electronics, so replace
microphone console.
Total loss of all
functionality on a single
microphone.
Mic ROM error
IPXX MIC FAULT-09
XX=01 to 20
(Mic Processor stops)
•
Replace microphone console.
Loss of All-Call
functionality on a single
SMC02 microphone
(standard SMC02 units
only)
All Call PTT
Contact Fault
IP01 ALLCALL PTT
Audio Input 01
or
IP02 ALLCALL PTT
Audio Input 02
•
Check hardwired PTT wiring between
the appropriate microphone and the
Router.
•
Replace microphone console.
•
Replace Router.
Loss of Speak Now LED
functionality on a single
SMC02 microphone
(standard SMC02 units
only)
LED fault
SPEAK-NOW
IP01 SPEAK LED
Audio Input 01
or
IP02 SPEAK LED
Audio Input 02
•
Check wiring between Router and
SPEAK-NOW LEDs on the appropriate
microphone.
•
Replace microphone console.
•
Replace Router.
Loss of All-Call LED
functionality on a single
SMC microphone
(standard SMC02 units
only)
LED fault
ALL-CALL-ONLY
IP01 ALLCALL LED
Audio Input 01
or
IP02 ALLCALL LED
Audio Input 02
•
Check wiring between Router and
ALLCALL LEDs on the appropriate
microphone.
•
Replace microphone console.
•
Replace Router.
Issue: 02 complete, approved