background image

Insulated

 

moun ng

Screw

-

in

 

heater

 

R

 

1½“

ASKO

HEAT

+

ASKO

HEAT

+

MVGASV_012

-

6391_V02_en

 

www.askoma.com

Page

 

1

Fitting

 

instructions,

 

user

 

manual

 

and

 

service

Screw

-

in

 

heater

 

R

 

1½“

 

for

 

drinking

 

and

 

hea ng

 

water

1.75

 

to

 

5.2

 

kW

x

AHIR

-

BI

-

plus

-

1.75

x

AHIR

-

BI

-

plus

-

3.5

x

AHIR

-

BI

-

plus

-

4.4

x

AHIR

-

BI

-

plus

-

5.2

Index

 

General

 

safety

 

and

 

assembly

 

informa on

 

Page

 

2

Opera ng

 

instruc ons

Page

 

3

Assembly

 

instruc ons

Page

 

4

User

 

manual

Page

 

5

Opera ng

 

condi ons

Page

 

6

Electrical

 

diagram

 

Page

 

7

 

/

 

8

Service

Page

 

9

Malfunc on

Page

 

9

Please

 

keep

 

in

 

a

 

safe

 

place

Содержание AHIR-BI-plus-1.75

Страница 1: ...for drinking and hea ng water 1 75 to 5 2 kW x AHIR BI plus 1 75 x AHIR BI plus 3 5 x AHIR BI plus 4 4 x AHIR BI plus 5 2 Index General safety and assembly informa on Page 2 Opera ng instruc ons Page...

Страница 2: ...n the device respec vely inside the housing cover or can be found in the fi ng instruc ons user manuals x Do not place the device into opera on un l a er having read the user manual x These devices ma...

Страница 3: ...tch has to be le in posi on Schwarzstahlspeicher factory se ng When installing the hea ng element into a stainless steel or chrome steel boiler the slide switch DIP switch has to be switched to posi o...

Страница 4: ...Fill the tank and check for leaks 2 Connect the screw in heater electrically Plug Z1 Connect the power supply to the hea ng element as follows Connec on 1 L1 Connec on 2 L2 Connec on 3 L3 Connec on N...

Страница 5: ...o approx 65 C When the temperature is reached the device switches o and on again automa cally if necessary Safety temperatur limiter If the safety temperature limiter has tripped you can reset it with...

Страница 6: ...e toggles on or o very fast flashing at start and stop update LED 2 CONNECTION Red Connec on to local network LAN Green LAN Ethernet connected to a switch hub or router Yellow flashing Data communica...

Страница 7: ...OHEAT ASKOHEAT MVGASV_012 6391_V02_en www askoma com Page 7 Electrical diagram WARNING All power supply circuits must have been switched o before accessing the connec on terminals Electrical and conne...

Страница 8: ..._012 6391_V02_en www askoma com Page 8 Electrical diagram WARNING All power supply circuits must have been switched o before accessing the connec on terminals Electrical and connec on diagram 3 5 kW 5...

Страница 9: ...mperature limiter trips there is a fault or error A qualified expert must inspect the system in this case 2x year When the heater is used in hard water areas it must be regularly descaled It is impera...

Отзывы: