background image

Insulated

 

moun ng

Screw

-

in

 

heater

 

R

 

1½“

ASKO

HEAT

+

ASKO

HEAT

+

MVGASV_012

-

6391_V02_en

 

www.askoma.com

Page

 

9

Service

1.

 

2.

 

Malfunction

Reset

For

 

technical

 

data

 

see

 

the

 

data

 

sheet

Subject

 

to

 

technical

 

altera ons

See

 

user

 

manual

 

for

 

the

 

quali

fi

ed

 

installer

.

The

 

device

 

must

 

be

 

cleaned

 

(descaled)

 

with

 

a

 

suitable

 

professional

 

descaling

 

agent,

 

e.

 

g.

 

citric

 

acid.

If

 

the

 

safety

 

temperature

 

limiter

 

trips,

 

there

 

is

 

a

 

fault

 

or

 

error.

 

A

 

quali

fi

ed

 

expert

 

must

 

inspect

 

the

 

system

 

in

 

this

 

case.

2x

 

/

 

year

 

When

 

the

 

heater

 

is

 

used

 

in

 

hard

 

water

 

areas

 

it

 

must

 

be

regularly

 

descaled.

 

It

 

is

 

impera ve

 

that

 

the

 

local

 

circumstances

 

are

 

paid

 

a en

­

on

 

to.

 

The

 

build

 

up

 

of

 

scale

 

in

 

the

 

hea ng

 

element

 

can

 

lead

 

to

 

the

 

ac va on

 

of

 

the

 

safety

 

temperature

 

limiter

 

or

 

thermal

overloading

 

thereby

 

destroying

 

the

 

hea ng

 

elements.

In

 

such

 

cases

 

the

 

guarantee

 

is

 

not

 

valid!

New

Needs

 

cleaning

The

 

version

 

currently

 

valid

 

can

 

be

 

downloaded

 

under

 

"Downloads"

 

from

 

our

 

homepage

Содержание AHIR-BI-plus-1.75

Страница 1: ...for drinking and hea ng water 1 75 to 5 2 kW x AHIR BI plus 1 75 x AHIR BI plus 3 5 x AHIR BI plus 4 4 x AHIR BI plus 5 2 Index General safety and assembly informa on Page 2 Opera ng instruc ons Page...

Страница 2: ...n the device respec vely inside the housing cover or can be found in the fi ng instruc ons user manuals x Do not place the device into opera on un l a er having read the user manual x These devices ma...

Страница 3: ...tch has to be le in posi on Schwarzstahlspeicher factory se ng When installing the hea ng element into a stainless steel or chrome steel boiler the slide switch DIP switch has to be switched to posi o...

Страница 4: ...Fill the tank and check for leaks 2 Connect the screw in heater electrically Plug Z1 Connect the power supply to the hea ng element as follows Connec on 1 L1 Connec on 2 L2 Connec on 3 L3 Connec on N...

Страница 5: ...o approx 65 C When the temperature is reached the device switches o and on again automa cally if necessary Safety temperatur limiter If the safety temperature limiter has tripped you can reset it with...

Страница 6: ...e toggles on or o very fast flashing at start and stop update LED 2 CONNECTION Red Connec on to local network LAN Green LAN Ethernet connected to a switch hub or router Yellow flashing Data communica...

Страница 7: ...OHEAT ASKOHEAT MVGASV_012 6391_V02_en www askoma com Page 7 Electrical diagram WARNING All power supply circuits must have been switched o before accessing the connec on terminals Electrical and conne...

Страница 8: ..._012 6391_V02_en www askoma com Page 8 Electrical diagram WARNING All power supply circuits must have been switched o before accessing the connec on terminals Electrical and connec on diagram 3 5 kW 5...

Страница 9: ...mperature limiter trips there is a fault or error A qualified expert must inspect the system in this case 2x year When the heater is used in hard water areas it must be regularly descaled It is impera...

Отзывы: