Servicemanual WM60
29
Switch off, and then on main power.
S6
•Wait for at least 5 seconds
•Press down button S6
•Turn on the power
•Pressing S6 when power on followed by 3 pushes on S6 within 5 sec enters the service menu.
NOTE!
Make all selections. Pressing S13 stores all selections made in service menu and leaves service mode.
Turn
J1
Tracking data reed out
SP: (software programming date: year week
CM: (control unit manufacturing date: year week
SV: (Software version)
SV: (Software version)
NC: Number of cycles
Press S14 next step is accessed.
Failure reed out
Rotating J1 will display 2nd and 3rd last deviating fault, ex “Thermistor fault (2); 30” , “Over flow (3); 20”
Failure record is cleared by total reset
Pressing S14 next step is accessed.
Diagnostics
Separate test of auxiliary components.
Rotating J1 each component will be turned on (with a 1 sec delay) and inputs detected in sequence:
“Testing” (no component),
“Testing valve 1” (inlet valve 1 on),
“Testing valve 2” (inlet valve 2 on),
“Testing valve SM” (inlet valve 1 and 2 on),
“Testing heater” (heater on until max 60°C),
“Testing motor” (normal action),
“Testing drain” (drain pump on),
“Testing spin” (spin sequence, drain pump on),
“Testing door”.
Pressing S14 components will be off and next step is accessed.
Rinse setting
Turn J1 counter clockwise ”3 rinses” default or clockwise ” 5 rinses”
Pressing S14 next step is accessed.
Temperature °C/°F
Turn J1 counter clockwise ”°C” default or clockwise” °F”
Pressing S14 next step is accessed.
Spin speed
Turn J1 counter clockwise 1500 rpm, 1600 rpm, 1700 rpm, 1800 rpm, default or clockwise 1800 rpm, 1700 rpm ...
Pressing S14 next step is accessed or S13 to store or leave service mode.
Total reset
By pressing S14 when power on the software total resets (return to default values of all settings). Service menu
settings and parameters only re-programmable in in-line programming excluded (shall not reset).
Service menu WM60.2
S1
J1
S10
S8
S2 S3
S13
S11
S14
S12
S9
S4 S5 S6 S7
LCD
L3 L4
L1
L5
L2
L6